Objective comparison of high‐contrast spatial resolution and low‐contrast detectability for various clinical protocols on multiple CT scanners
Author(s) -
Racine Damien,
Viry Anaïs,
Becce Fabio,
Schmidt Sabine,
Ba Alexandre,
Bochud François O.,
Edyvean Sue,
Schegerer Alexander,
Verdun Francis R.
Publication year - 2017
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1002/mp.12224
Subject(s) - imaging phantom , contrast (vision) , image resolution , image quality , nuclear medicine , scanner , protocol (science) , computer science , medicine , artificial intelligence , alternative medicine , pathology , image (mathematics)
Purpose We sought to compare objectively computed tomography ( CT ) scanner performance for three clinically relevant protocols using a task‐based image quality assessment method in order to assess the potential for radiation dose reduction. Methods Four CT scanners released between 2003 and 2007 by different manufacturers were compared with four CT scanners released between 2012 and 2014 by the same manufacturers using ideal linear model observers ( MO ): prewhitening ( PW ) MO and channelized Hotelling ( CHO ) MO with Laguerre‐Gauss channels for high‐contrast spatial resolution and low‐contrast detectability ( LCD ) performance, respectively. High‐contrast spatial resolution was assessed using a custom‐made phantom that enabled the computation of the target transfer function ( TTF ) and noise power spectrum ( NPS ). Low‐contrast detectability was assessed using a commercially available anthropomorphic abdominal phantom providing equivalent diameters of 24, 29.6, and 34.6 cm. Three protocols were reviewed: a head (trauma) and an abdominal (urinary stones) protocol were applied to assess high‐contrast spatial resolution performance; and another abdominal (focal liver lesions) protocol was applied for LCD . The liver protocol was tested using fixed and modulated tube currents. The PW MO was proposed for assessing high‐contrast detectability performance of the various CT scanners. Results Compared with older generation CT scanners, three newer systems displayed significant improvements in high‐contrast detectability over that of their predecessors. A fourth, newer system had lower performance. The CHO MO was appropriate for assessing LCD performance and revealed that an excellent level of image quality could be obtained with newer scanners at significantly lower dose levels. Conclusions This study shows that MO can objectively benchmark CT scanners using a task‐based image quality method, thus helping to estimate the potential for further dose reductions offered by the latest systems. Such an approach may be useful for adequately and quantitatively comparing clinically relevant image quality among various scanners.