A feasibility study of a deuterium–deuterium neutron generator‐based boron neutron capture therapy system for treatment of brain tumors
Author(s) -
Hsieh Mindy,
Liu Yingzi,
Mostafaei Farshad,
Poulson Jean M.,
Nie Linda H.
Publication year - 2017
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1002/mp.12051
Subject(s) - neutron generator , neutron , imaging phantom , neutron capture , neutron source , collimator , materials science , neutron temperature , nuclear physics , nuclear medicine , radiochemistry , physics , optics , chemistry , medicine
Purpose Boron neutron capture therapy ( BNCT ) is a binary treatment modality that uses high LET particles to achieve tumor cell killing. Deuterium–deuterium ( DD ) compact neutron generators have advantages over nuclear reactors and large accelerators as the BNCT neutron source, such as their compact size, low cost, and relatively easy installation. The purpose of this study is to design a beam shaping assembly ( BSA ) for a DD neutron generator and assess the potential of a DD ‐based BNCT system using Monte Carlo ( MC ) simulations. Methods The MC model consisted of a head phantom, a DD neutron source, and a BSA . The head phantom had tally cylinders along the centerline for computing neutron and photon fluences and calculating the dose as a function of depth. The head phantom was placed at 4 cm from the BSA . The neutron source was modeled to resemble the source of our current DD neutron generator. A BSA was designed to moderate and shape the 2.45‐MeV DD neutrons to the epithermal (0.5  eV to 10 keV) range. The BSA had multiple components, including moderator, reflector, collimator, and filter. Various materials and configurations were tested for each component. Each BSA layout was assessed in terms of the in‐air and in‐phantom parameters. The maximum brain dose was limited to 12.5 Gray‐Equivalent (Gy‐Eq) and the skin dose to 18 Gy‐Eq. Results The optimized BSA configuration included 30 cm of lead for reflector, 45 cm of LiF, and 10 cm of MgF 2 for moderator, 10 cm of lead for collimator, and 0.1 mm of cadmium for thermal neutron filter. Epithermal flux at the beam aperture was 1.0 × 10 5  n epi /cm 2 ‐s; thermal‐to‐epithermal neutron ratio was 0.05; fast neutron dose per epithermal was 5.5 × 10 −13  Gy‐cm 2 / φ epi , and photon dose per epithermal was 2.4 × 10 −13  Gy‐cm 2 / φ epi . The AD , AR , and the advantage depth dose rate were 12.1 cm, 3.7, and 3.2 × 10 −3   cG y‐Eq/min, respectively. The maximum skin dose was 0.56 Gy‐Eq. The DD neutron yield that is needed to irradiate in reasonable time was 4.9 × 10 13  n/s. Conclusions Results demonstrated that a DD ‐based BNCT system could be designed to produce neutron beams that have acceptable in‐air and in‐phantom characteristics. The parameter values were comparable to those of existing BNCT facilities. Continuing efforts are ongoing to improve the DD neutron yield.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here