Reduced vascular trauma after temporary occlusion with modified biemer and yasargil clips
Author(s) -
Dujovny Manuel,
Munoz Guillermo,
Nelson Debra,
Langhi Roberto,
Fein Jack M.,
Ba Nir Kossovsky
Publication year - 1981
Publication title -
microsurgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.031
H-Index - 63
eISSN - 1098-2752
pISSN - 0738-1085
DOI - 10.1002/micr.1920020307
Subject(s) - clips , medicine , occlusion , surgery , vascular occlusion
The Biemer and Yasargil microvascular clips that are currently available commercially can traumatize the vascular endothelium. In an effort to resolve this problem, both clip designs were structurally modified by changing the length, width, and surface of the clip blades in various ways. Also, the occlusion force of the clips was set at either 15 or 30 g. Studies on the carotid arteries of 140 rats showed a correlation between the structural and mechanical alterations of the clips and the degree of endothelial trauma produced by temporary occlusion for 1 hour. The most favorable results were obtained with a Biemer clip that had long, wide, smooth blades and an occluding force of 15 g.