Subject(s) - materials science , metallurgy , austenitic stainless steel , corrosion , indentation hardness , pitting corrosion , austenite , crevice corrosion , microstructure
Mechanical and corrosion properties of spot‐welded high‐strength austenitic stainless steels EN 1.4318 2H/C1150 and EN 1.4318 2H/C850 were studied. Microhardness measurements, lap shear and cross‐tension tests, corrosion fatigue tests and corrosion tests were carried out. The corrosion environment was 3.5% sodium chloride solution at +50 °C in the corrosion fatigue tests and 3.5% sodium chloride solution at ambient temperature in the electrochemical pitting corrosion tests. Stainless steel EN 1.4318 2H/C850, t  = 1.92 mm, exhibited better fatigue endurance than EN 1.4318 2H/C1150, t  = 1.2 mm, and EN 1.4318 2H/C850, t  = 1.0 mm, stainless steels did. There were no significant differences between the stainless steels of different strength levels (2H/C850 vs . 2H/C1150) in the line load range analysis of the fatigue data. High hardness gradient was found in the heat‐affected zone (HAZ) of EN 1.4318 2H/C1150 stainless steels. EN 1.4318 2H/C1150, t  = 1.2 mm, stainless steels seemed to have slightly higher lap shear strength with the same nugget diameter as EN 1.4318 2H/850, t  = 1.9 mm, stainless steel. In the case of EN 1.4318 2H/C1150 stainless steel increase in the nugget diameter bigger than required 5√ t did not increase the cross‐tension force significantly. The pitting corrosion susceptibility of the spot‐welded samples and the base materials of the steels EN 1.4318 2H/C850 and EN 1.4318 2H/C1150, t  = 1.2 mm, was investigated by measuring the corrosion current for 1 h at +100 mV versus saturated calomel electrode (SCE) in 3.5% sodium chloride solution at ambient temperature. Pitting corrosion occurred in all spot‐welded samples but not in the base materials. There was a difference between the investigated steels in the location of the pits. In stainless steels EN 1.4318 2H/C850 the pits appeared around the spot weld, but in the steel EN 1.4318 2H/C1150, t  = 1.2 mm, the pits are located mainly at the spot‐weld area.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom