Premium
The use of electrochemical techniques for the investigation and monitoring of microbiologically influenced corrosion and its inhibition – a review
Author(s) -
Mansfeld F.
Publication year - 2003
Publication title -
materials and corrosion
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.487
H-Index - 55
eISSN - 1521-4176
pISSN - 0947-5117
DOI - 10.1002/maco.200390111
Subject(s) - corrosion , dielectric spectroscopy , electrochemical noise , seawater , brass , polarization (electrochemistry) , cathodic protection , electrochemistry , materials science , metallurgy , artificial seawater , chemistry , electrode , copper , biology , ecology
The background of several electrochemical techniques – recording of the corrosion potential E corr , electrochemical impedance spectroscopy (EIS), electrochemical noise analysis (ENA) and recording of potentiodynamic polarization curves – has been discussed and examples of the use of these techniques in studies of microbiologically influenced corrosion (MIC) and MIC inhibition have been presented. These examples range from the use of the polarization resistance R p and the noise resistance R n in corrosion monitoring in a sewer environment and a gas production field, respectively, to the application of EIS and ENA in the evaluation of the interaction of bacteria with protective coatings on steel exposed to natural seawater (NS). A more detailed analysis based on EIS and ENA of Corrosion protection of Al 2024, mild steel and brass in artificial seawater (AS) by bacteria such as B. subtilis, B. licheniformis, E. coli and Shewanella has been presented. Determination of the changes of R p and R n as well as E corr allows to propose appropriate mechanisms of MIC inhibition. These mechanisms have been confirmed in the case of S. algae by recording of anodic and cathodic potentiodynamic polarization curves after exposure to AS containing the bacteria for extended time periods.