z-logo
Premium
Analysis of Impact of Humidity and Temperature on Excimer Laser Ablation of Polyethylene Terephthalate, Polymethylmethacrylate, and Porcine Corneal Tissue
Author(s) -
Verma Shwetabh,
Kehrer Tobias,
Hesser Jürgen,
Arba Mosquera Samuel
Publication year - 2020
Publication title -
lasers in surgery and medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.888
H-Index - 112
eISSN - 1096-9101
pISSN - 0196-8092
DOI - 10.1002/lsm.23190
Subject(s) - ablation , materials science , fluence , cornea , relative humidity , laser , excimer laser , excimer , polyethylene terephthalate , optics , biomedical engineering , ablation zone , laser ablation , humidity , polyethylene , composite material , medicine , physics , thermodynamics
Background and Objectives To analyze the impact of humidity and temperature on excimer laser ablation of polyethylene terephthalate (PET), polymethylmethacrylate (PMMA) and porcine corneal tissue, and an ablation model to compensate for the temperature and humidity changes on ablation efficiency. Study Design/Materials and Methods The study was conducted using an AMARIS 1050RS (Schwind eye‐tech‐solutions) placed inside a climate chamber at ACTS. Ablations were performed on PET, PMMA, and porcine cornea. The impact of a wide range of temperature (~18°C to ~30°C) and relative humidity (~25% to ~80%) on laser ablation outcomes was tested using nine climate test settings. For porcine eyes, change in defocus was calculated from the difference of post‐ablation to pre‐ablation average keratometry readings. Laser scanning deflectometry was performed to measure refractive change achieved in PMMA. Multiple linear regression was performed using the least square method with predictive factors: temperature, relative humidity, time stamp. Influence of climate settings was modeled for pulse energy, pulse fluence, ablation efficiency on PMMA and porcine cornea tissue. Results Temperature changes did not affect laser pulse energy, pulse fluence (PET), and ablation efficiency (on PMMA or porcine corneal tissue) significantly. Changes in relative humidity were critical and significantly affected laser pulse energy, high fluence and low fluence. The opposite trend was observed between the ablation performance on PMMA and porcine cornea. Conclusions The proposed well‐fitting multi‐linear model can be utilized for compensation of temperature and humidity changes on ablation efficiency. Based on this model, a working window for optimum operation has been found (temperature 18°C to 28°C and relative humidity 25% to 65%) for a maximum deviation of ±2.5% in ablation efficiency in PMMA and porcine corneal tissue. Lasers Surg. Med. © 2019 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here