Temperature Depth Profiles Induced in Human Skin In Vivo Using Pulsed 975 nm Irradiation
Author(s) -
Milanic Matija,
Cenian Adam,
Verdel Nina,
Cenian Witold,
Stergar Jost,
Majaron Boris
Publication year - 2019
Publication title -
lasers in surgery and medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.888
H-Index - 112
eISSN - 1096-9101
pISSN - 0196-8092
DOI - 10.1002/lsm.23108
Subject(s) - laser , irradiation , materials science , human skin , photothermal therapy , optics , radiant energy , optoelectronics , biomedical engineering , radiation , medicine , nanotechnology , genetics , physics , nuclear physics , biology
Background and Objectives The aim of this study was to determine the temperature depth profiles induced in human skin in vivo by using a pulsed 975 nm diode laser (with 5 ms pulse duration) and compare them with those induced by the more common 532 nm (KTP) and 1,064 nm (Nd:YAG) lasers. Quantitative assessment of the energy deposition characteristics in human skin at 975 nm should help design of safe and effective treatment protocols when using such lasers. Study Design/Materials and Methods Temperature depth profiles induced in the human skin by the three lasers were determined using pulsed photothermal radiometry (PPTR). This technique involves time‐resolved measurement of mid‐infrared emission from the irradiated test site and reconstruction of the laser‐induced temperature profiles using an earlier developed optimization algorithm. Measurements were performed on volar sides of the forearms in seven volunteers with healthy skin. At irradiation spot diameters of 3–4 mm, the radiant exposures were 0.24, 0.36, and 5.7 J/cm 2 for the 975, 532, and 1,064 nm lasers, respectively. Results Upon normalization to the same radiant exposure of 1 J/cm 2 , the assessed maximum temperature rise in the epidermis averaged 0.8 °C for the 975 nm laser, 7.4 °C for the 532 nm, and 0.6 °C for the 1,064 nm laser. The characteristic subsurface depth to which 50% of the absorbed laser energy was deposited was on average 0.31 mm at 975 nm irradiation, and slightly deeper at 1,064 nm, and 0.15 mm at 532 nm. The experimentally obtained relations were reproduced in a dedicated numerical simulation. Conclusions The assessed energy deposition characteristics show that the pulsed 975 nm diode laser is very suitable for controlled heating of the upper dermis as required, for example, for nonablative skin rejuvenation. The risks of nonselective overheating of the epidermis and subcutis are significantly reduced in comparison with irradiation at 532 and 1,064 nm, respectively. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here