z-logo
Premium
Laser reshaping of costal cartilage for transplantation
Author(s) -
Baum Olga I.,
Soshnikova Yulia M.,
Sobol Emil N.,
Korneychuk Andrey Ya.,
Obrezkova Mariya V.,
Svistushkin Valeriy M.,
Timofeeva Oxana K.,
Lunin Valeriy V.
Publication year - 2011
Publication title -
lasers in surgery and medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.888
H-Index - 112
eISSN - 1096-9101
pISSN - 0196-8092
DOI - 10.1002/lsm.21077
Subject(s) - cartilage , costal cartilage , laser , materials science , irradiation , biomedical engineering , anatomy , optics , medicine , physics , nuclear physics
Background and Objective Laser reshaping of cartilage is a new effective and safe technique for correction of nasal septum and ear deformities. Costal cartilage is a most suitable natural material for transplantation. The problem is to obtain stable proper shape of cartilage implants. The objective of this article is to study reshaping of porcine costal cartilage for larynx stenosis surgery using Erbium glass fiber laser. Materials and Methods Porcine cartilage plates 3 mm in thickness were mechanically curved and irradiated (1) on one side (stretched or compressed) and (2) on both sides with different sequence. Irradiation was performed using a 1.56 µm laser with power varied from 1 to 2.5 W, exposure time from 5 to 20 seconds, spot diameter of 2.5 mm, pulse duration of 500 milliseconds, pulse repetition rate of 1.4 Hz. For each laser setting, stable curvature radius was measured during 24 hours after the experiment. Irradiated samples were analyzed by means of differential scanning calorimerty (DSC) to reveal the collagen denaturation degree. Results The optimum laser setting for stable reshaping of costal cartilage without visual thermal damage of cartilage matrix was established: laser power of 2.2 W, exposure time of 6 seconds. Nonlinear thermomechanical behavior of cartilage in the course of its laser reshaping is experimentally revealed. The influence of irradiation sequence on the curvature radius of cartilage implant is found for the first time. It is shown that (1) it is possible to use laser reshaping technique for making stable proper shape of costal cartilage, and (2) primary irradiation of compressed side followed with an irradiation of stretched side is more effective than reverse sequence of laser treatment. DSC analysis showed that thermal effect of irradiated specimens (2.58–3.79 J/g) was slightly lower that that for intact cartilage specimens and considerably lower than that for denaturation of collagen (65 ± 5 J/g). Conclusions It is possible to use laser reshaping technique for preparation of stable cartilage implants. Nonlinear thermomechanical behavior of cartilage is experimentally revealed. The influence of irradiation sequence on curvature radius of cartilage grafts is established for the first time. Lasers Surg. Med. 43:511–515, 2011. © 2011 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here