z-logo
Premium
Laser‐tissue soldering with biodegradable polymer films in vitro: Film surface morphology and hydration effects
Author(s) -
Sorg Brian S.,
Welch Ashley J.
Publication year - 2001
Publication title -
lasers in surgery and medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.888
H-Index - 112
eISSN - 1096-9101
pISSN - 0196-8092
DOI - 10.1002/lsm.1053
Subject(s) - materials science , soldering , plga , ultimate tensile strength , composite material , biomedical engineering , polymer , nanotechnology , medicine , nanoparticle
Background and Objective Previous research introduced the concept of using biodegradable polymer film reinforcement of a liquid albumin solder for improvement of the tensile strength of repaired incisions in vitro. In this study, the effect of creating small pores in the PLGA films on the weld breaking strength is studied. Additionally, the effect of hydration on the strength of the reinforced welds is investigated. Study Design/Materials and Methods A 50%(w/v) bovine serum albumin solder with 0.5 mg/mL Indocyanine Green dye was used to repair an incision in bovine aorta. The solder was coagulated with an 806‐nm CW diode laser. A poly( DL ‐lactic‐co‐glycolic acid) (PLGA) film was used to reinforce the solder (the controls had solder but no reinforcement). Breaking strengths were measured acutely and after hydration in saline for 1 and 2 days. The data were analyzed by ANOVA ( P  < 0.05) and multiple comparisons of means were performed using the Newman–Keuls test. Results The creation of pores in the PLGA films qualitatively improved the film flexibility without having an apparent adverse effect on the breaking strength, while the actual technique of applying the film and solder had more of an effect. The acute maximum average breaking strengths of some of the film reinforced specimens (114.7 g–134.4 g) were significantly higher ( P  < 0.05) than the acute maximum average breaking strength of the unreinforced control specimens (68.3 g). Film reinforced specimens were shown to have a statistically significantly higher breaking strength than unreinforced controls after 1‐ and 2‐day hydration. Conclusions Reinforcement of liquid albumin solders in laser‐assisted incision repair appears to have advantages over conventional methods that do not reinforce the cohesive strength of the solder in terms of acute breaking strength and after immersion in moist environments for short periods of time. Using a film with the solder applied to one surface only may be advantageous over other techniques. Lasers Surg. Med. 28:297–306, 2001. © 2001 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here