Background and Objectives Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatologic surgery. Since optimization of CSC permits the safe use of higher light doses, which improves therapeutic outcome in many patients with superficial skin lesions, studies have focused on understanding spray–surface interactions and cooling dynamics. The objective of this study is to measure accurately temperature variations at the sprayed surface and the effects of spurt duration (Δ t ) and nozzle‐to‐sprayed surface distance ( L ) on cooling dynamics during CSC. Study Design/Materials and Methods A fast‐response temperature measurement sensor is built using thin (20 μm) aluminum foil placed on top of a poly methyl‐methacrylate resin (Plexiglass ® ) with a 50 μm bead diameter thermocouple positioned in between. Liquid film residence time ( t r ) and minimum surface temperature ( T min ) are systematically measured as a function of Δ t and L . Results Two distinct spray–surface interaction mechanisms are recognized. The transition between them occurs at a critical length L c ≈25–30 mm. Noticeable characteristics include: (1) for spurts at L  <  L c , shorter t r , and lower T min are reached as compared to L  >  L c , T min is dependent on Δ t and L , while t r is a function of Δ t only; (2) for spurts at L  >  L c , T min still depends on L but not on Δ t , while t r becomes a function of both Δ t and L . Finally, for all Δ t , t r reaches a maximum at L  = 40 mm. Conclusions Based on our results, a good choice to achieve low T min and t r for the treatment of superficial skin lesions may be met by using Δ t of ≈30–50 milliseconds and the shortest spray distance that is tolerable by the patient. Spurt durations (Δ t ) of more than 30–50 milliseconds at spray distances ( L ) greater than L c lead to higher T min and longer t r . These parameters may be appropriate for laser therapy of deeper targets. Lasers Surg. Med. 32:152–159, 2003. © 2003 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here