z-logo
Premium
Quantifying vocal fold wound‐healing biomechanical property changes
Author(s) -
Dion Gregory R.,
Guda Teja,
Mukudai Shigeyuki,
Bing Renjie,
Lavoie JeanFrancois,
Branski Ryan C.
Publication year - 2020
Publication title -
the laryngoscope
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.181
H-Index - 148
eISSN - 1531-4995
pISSN - 0023-852X
DOI - 10.1002/lary.27999
Subject(s) - medicine , nuclear medicine , post hoc , vocal folds , analysis of variance , anatomy , biomedical engineering , orthodontics , larynx
Objectives Development of novel vocal fold (VF) therapeutics is limited by a lack of standardized, meaningful outcomes. We hypothesize that automated microindentation‐based VF biomechanical property mapping matched to histology permits quantitative assessment. Study Design Ex vivo. Methods Twelve anesthetized New Zealand white rabbits underwent endoscopic right VF injury. Larynges were harvested/bisected day 7, 30, or 60 (n = 4/group), with four uninjured controls. Biomechanical measurements (normal force, structural stiffness, and displacement at 1.96 mN) were calculated using automated microindentation mapping (0.3 mm depth, 1.2 mm/s, 2 mm spherical indenter) with a grid overlay (>50 locations weighted toward VF edge, separated into 14 zones). Specimens were marked/fixed/sectioned, and slides matched to measurement points. Results In the injury zone, normal force/structural stiffness (mean, standard deviation [SD]/mean, SD) increased from uninjured (2.2 mN, 0.64/7.4 mN/mm, 2.14) and day 7 (2.7 mN, 0.75/9.0 mN/mm, 2.49) to day 30 (4.3 mN, 2.11/14.2 mN/mm, 7.05) and decreased at 60 days (2.7 mN, 0.77/9.1 mN/mm, 2.58). VF displacement decreased from control (0.28 mm, 0.05) and day 7 (0.26 mm, 0.05) to day 30 (0.20 mm, 0.05), increasing at day 60 (0.25 mm, 0.06). A one‐way ANOVA was significant; Tukey's post hoc test confirmed day‐30 samples differed from other groups ( P < 0.05), consistent across adjacent zones. Zones far from injury remained similar across groups ( P = 0.143 to 0.551). These measurements matched qualitative histologic variations. Conclusion Quantifiable VF biomechanical properties can be linked to histology. This technological approach is the first to simultaneously correlate functional biomechanics with histology and is ideal for future preclinical studies. Level of Evidence NA Laryngoscope , 130:454–459, 2020

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here