z-logo
Premium
Surface charge modification decreases Pseudomonas aeruginosa adherence in vitro and bacterial persistence in an in vivo implant model
Author(s) -
Kao W. Katherine,
Gag Patricia M.,
Vogel Joseph P.,
Chole Richard A.
Publication year - 2017
Publication title -
the laryngoscope
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.181
H-Index - 148
eISSN - 1531-4995
pISSN - 0023-852X
DOI - 10.1002/lary.26499
Subject(s) - biofilm , in vivo , surface modification , pseudomonas aeruginosa , surface charge , implant , bacteria , in vitro , titanium , adhesion , microbiology and biotechnology , biophysics , chemistry , materials science , medicine , biology , composite material , surgery , biochemistry , genetics , organic chemistry
Objective Chronic, persistent infections complicate otologic procedures utilizing implantable devices such as cochlear implants or tympanostomy tubes. These infections are thought to be due to the establishment of microbial biofilms on implant surfaces. To address this issue, we hypothesized that surface charge modification may inhibit the formation of Pseudomonas aeruginosa biofilms on implant surfaces in vitro and in vivo. Study Design We evaluated the effect of surface charge modification on bacterial biofilm formation by assessing the effect of the surface charge on bacterial adhesion in vitro and bacterial persistence in vivo. Methods To study the effect of surface charge in vitro, the surface wells in culture plates were modified using a layer‐by‐layer polyelectrolyte assembly method. Bacterial adherence was measured at 30‐, 60‐, and 120‐minute intervals. To study the effect of surface charge modification in vivo, the surface of titanium microscrews was similarly modified and then surgically implanted into the dorsal calvaria of adult rats and inoculated with bacteria. Two weeks after implantation and inoculation, the number of bacteria remaining in vivo was evaluated. Results Surface charge modification results in a significant decrease in adherence of bacteria in vitro. Surface charge modification of titanium microscrew implants also resulted in a significant decrease in P. aeruginosa recovered 2 weeks after surgical implantation. Conclusion Charge modification decreases the number of bacteria adherent to a surface in vitro and decreases the risk and severity of implant infection in an in vivo rat infection model. These results have promising biomedical applications. Level of Evidence NA. Laryngoscope , 127:1655–1661, 2017

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here