z-logo
Premium
The utility of common surgical instruments for pediatric adenotonsillectomy
Author(s) -
Thottam Prasad John,
Christenson Jennifer R.,
Cohen David S.,
Metz Christopher M.,
Saraiya Sonal S.,
Haupert Michael S.
Publication year - 2015
Publication title -
the laryngoscope
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.181
H-Index - 148
eISSN - 1531-4995
pISSN - 0023-852X
DOI - 10.1002/lary.24830
Subject(s) - tonsillectomy , medicine , adenoidectomy , intensive care medicine , surgery
Objectives/Hypothesis To evaluate the correlation between surgical instrumentation and intraoperative surgical time, postoperative hemorrhage, and associated healthcare cost for pediatric adenotonsillectomy. Study Design Retrospective chart analysis. Methods Chart data were collected from pediatric patients who underwent adenotonsillectomy from 2011 to 2013. Monopolar electrocautery, radiofrequency ablation, and PlasmaBlade instruments were compared for intraoperative surgical time and postoperative hemorrhage rate. Univariate analysis of variance (ANOVA) and χ[2][Ramos SD, 2013] analysis was utilized to evaluate differences between instrumentation and variables. Cost analysis examining instrumentation and intraoperative anesthesia was also reviewed. Results A total of 1,280 patients who underwent adenotonsillectomy were evaluated. There was no significant overall difference in age, sex, or preoperative diagnosis identified between the three instrumentation groups. When examining the various instruments' effect on procedure time in minutes, univariate ANOVA demonstrated a significant difference overall among the three groups ( F  = 8.79; P  < .001). Post‐hoc pairwise comparisons identified significantly faster surgical times for monopolar cautery than either PlasmaBlade ( P  = .03) or radiofrequency ablation ( P  < .001). The difference in the number of patients who experienced a postoperative bleed by instrument was not statistically significant (χ 2  = 2.36; P  = .31). After instrumentation expenses were added to anesthesia cost, the overall average costs by instrument and surgical time were estimated to be $30.04 for monopolar cautery, $246.95 for PlasmaBlade, and $244.32 for radiofrequency ablation. Conclusions The ideal surgical instrumentation should be cost and time efficient with a low complication rate. Monopolar cautery was associated with a statistically significant lower intraoperative surgical time, similar postoperative hemorrhage rates, and lower operative costs when compared to radiofrequency ablation and PlasmaBlade. Level of Evidence 4 Laryngoscope , 125:475–479, 2015

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here