z-logo
Premium
Comparison of 2‐Dimensional Shear Wave Elastographic Measurements Using ElastQ Imaging and SuperSonic Shear Imaging: Phantom Study and Clinical Pilot Study
Author(s) -
Hwang Jisun,
Yoon Hee Mang,
Jung Ah Young,
Lee Jin Seong,
Cho Young Ah
Publication year - 2020
Publication title -
journal of ultrasound in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.574
H-Index - 91
eISSN - 1550-9613
pISSN - 0278-4297
DOI - 10.1002/jum.15108
Subject(s) - repeatability , medicine , imaging phantom , intraclass correlation , elastography , nuclear medicine , reproducibility , biomedical engineering , radiology , ultrasound , statistics , mathematics
Objectives To compare the feasibility and clinical applicability of ElastQ imaging (Philips Healthcare, Best, the Netherlands) with that of SuperSonic shear imaging (SSI; SuperSonic Imagine, Aix‐en‐Provence, France) using an elastographic phantom and a pilot study of patients. Methods Two‐dimensional shear wave elastography measurement was performed by ElastQ imaging and SSI by 2 radiologists. An elastographic phantom with 5 target elasticities at 2 acquisition depths was used. The coefficients of variation and intraclass correlation coefficients (ICCs) were evaluated for repeatability and interobserver agreement, respectively. The mean elasticities of the systems at each target were compared. The proportions of measurements that were out of the range of expected values and measurement errors were calculated to determine accuracy. Liver stiffness (LS) was measured by both systems in 27 children and young adult patients with various liver diseases. Results Both systems provided high repeatability in elasticity measurements of phantom targets (coefficients of variation, 0.69%–15.82%), and there was excellent interobserver agreement (ICC, 0.992). Most (90%) mean elasticities of targets were significantly different between the techniques ( P  ≤ .002) and acquisition depths ( P  ≤ .004). ElastQ imaging had significantly lower proportions of out‐of‐range measurements and measurement errors ( P  ≤ .003) than SSI. In patients with liver disease, LS measurements of the systems were strongly correlated (ρ = 0.955; P  < .001) and had excellent agreement (ICC, 0.951; P  < .001). Conclusions ElastQ imaging had comparably good results in terms of repeatability, interobserver agreement, and accuracy in the phantom model compared with SSI. The pilot patient study showed strong correlations in LS values between the systems.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here