z-logo
Premium
Simultaneous determination of N G ‐monomethyl‐ l ‐arginine, N G , N G ‐dimethyl‐ l ‐arginine, N G , N G′ ‐dimethyl‐ l ‐arginine, and l ‐arginine using monolithic silica disk‐packed spin columns and a monolithic silica column
Author(s) -
aka Satoko,
Sekine Masae,
Tsunoda Makoto,
Ozeki Yuji,
Fujii Kumiko,
Akiyama Kazufumi,
Shimoda Kazutaka,
Furuchi Takemitsu,
Katane Masumi,
Saitoh Yasuaki,
Homma Hiroshi
Publication year - 2014
Publication title -
journal of separation science
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.72
H-Index - 102
eISSN - 1615-9314
pISSN - 1615-9306
DOI - 10.1002/jssc.201400240
Subject(s) - chromatography , chemistry , arginine , calibration curve , high performance liquid chromatography , detection limit , solid phase extraction , analytical chemistry (journal) , amino acid , biochemistry
We have developed and validated a high‐performance liquid chromatography method that uses monolithic silica disk‐packed spin columns and a monolithic silica column for the simultaneous determination of N G ‐monomethyl‐ l ‐arginine, N G , N G ‐dimethyl‐ l ‐arginine, and N G , N G′ ‐dimethyl‐ l ‐arginine in human plasma. For solid‐phase extraction, our method employs a centrifugal spin column packed with monolithic silica bonded to propyl benzenesulfonic acid as a cation exchanger. After pretreatment, the methylated arginines are converted to fluorescent derivatives with 4‐fluoro‐7‐nitro‐2,1,3‐benzoxadiazole, and then the derivatives are separated on a monolithic silica column. l ‐Arginine concentration was also determined in diluted samples. Standard calibration curves revealed that the assay was linear in the concentration range 0.2–1.0 μM for methylated arginines and 40–200 μM for l ‐arginine. Linear regression of the calibration curve yielded equations with correlation coefficients of 0.999 ( r 2 ). The sensitivity was satisfactory, with a limit of detection ranging from 3.75 to 9.0 fmol for all four compounds. The RSDs were 4.3–4.8% (intraday) and 3.0–6.8% (interday). When this method was applied to samples from six healthy donors, the detected concentrations of N G ‐monomethyl‐ l ‐arginine, N G , N G ‐dimethyl‐ l ‐arginine, N G , N G′ ‐dimethyl‐ l ‐arginine and l ‐arginine were 0.05 ± 0.01, 0.41 ± 0.07, 0.59 ± 0.11, and 83.8 ± 30.43 μM ( n = 6), respectively.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom