z-logo
Premium
Determination of cysteine, homocysteine, cystine, and homocystine in biological fluids by HPLC using fluorosurfactant‐capped gold nanoparticles as postcolumn colorimetric reagents
Author(s) -
Zhang Lijuan,
Lu Biqi,
Lu Chao,
Lin JinMing
Publication year - 2014
Publication title -
journal of separation science
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.72
H-Index - 102
eISSN - 1615-9314
pISSN - 1615-9306
DOI - 10.1002/jssc.201300998
Subject(s) - cystine , chemistry , chromatography , cysteine , reagent , high performance liquid chromatography , homocysteine , biochemistry , organic chemistry , enzyme
We have demonstrated for the first time the suitability of fluorosurfactant‐capped spherical gold nanoparticles as HPLC postcolumn colorimetric reagents for the direct assay of cysteine, homocysteine, cystine, and homocystine. The success of this work was based on the use of an on‐line tris(2‐carboxyethyl)phosphine reduction column for cystine and homocystine. Several parameters affecting the separation efficiency and the postcolumn colorimetric detection were thoroughly investigated. Under the optimized conditions, cysteine, homocysteine, cystine, and homocystine in human urine and plasma samples were determined. Detection limits for cysteine, homocysteine, cystine, and homocystine ranged from 0.16–0.49 μM. The accuracy in terms of recoveries ranged between 94.0–102.1%. This proposed method was rapid, inexpensive, and simple.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here