z-logo
Premium
Buccal bone thickness adjacent to virtual dental implants following guided bone regeneration
Author(s) -
Phillips Daniel J.,
Swenson Dane T.,
Johnson Thomas M.
Publication year - 2019
Publication title -
journal of periodontology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.036
H-Index - 156
eISSN - 1943-3670
pISSN - 0022-3492
DOI - 10.1002/jper.18-0304
Subject(s) - buccal administration , dentistry , medicine , implant , fixation (population genetics) , dental implant , orthodontics , surgery , population , environmental health
Background Crestal bone thickness is a critical determinant of peri‐implant tissue stability. This retrospective observational study sought to quantify the buccal bone thickness achieved adjacent to virtual dental implants following guided bone regeneration (GBR) surgery and evaluate the influence of patient‐ and procedure‐related variables on buccal bone thickness. Methods Cone‐beam computed tomography (CBCT) images acquired from patients who had undergone GBR surgery between July 1, 2012, and November 7, 2016, were used for this analysis. In all cases, the GBR procedure involved a dense polytetrafluoroethylene (dPTFE) barrier membrane and a mineralized cortical particulate freeze‐dried bone allograft (FDBA). Eighty‐four virtual dental implants were placed at planned locations using CBCT images from 84 patients, and the adjacent buccal bone thickness was measured at each site. The effects of sex, age, estimated baseline ridge width, number of missing teeth in site, site type (tooth‐bounded versus terminal position in arch), dental arch (mandibular or maxillary), arch location (anterior or posterior), smoking status, titanium reinforcement in the membrane, membrane fixation, and tenting screw use were assessed. Results The mean post‐GBR buccal bone thickness adjacent to virtual dental implants was 2.24 ± 1.01 mm. Fifty‐nine of 84 virtual implants (70%) exhibited buccal bone thickness > 1.9 mm. GBR sites using membrane fixation produced significantly greater virtual implant buccal bone thickness than those without membrane fixation (2.31 ± 0.96 versus 1.15 ± 1.25 mm, P  = 0.012). Virtual implant buccal bone thickness also exhibited moderate correlation with estimated initial ridge width (r = 0.43, P  < 0.0001). The alveolar ridge at 81 virtual implant sites (96%) was classified as good or satisfactory, meaning dental implants were actually placed at these sites, with or without additional grafting at implant placement. Conclusions Observations in this study suggest GBR procedures using dPTFE membranes and FDBA result in favorable ridge dimensions for dental implant placement in most cases. However, additional augmentation at implant surgery may be necessary at ≈ 30% of sites, if buccal bone thickness > 1.9 mm is intended.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here