z-logo
Premium
Mechanical properties of a hierarchical electrospun scaffold for ovine anterior cruciate ligament replacement
Author(s) -
Pauly Hannah,
Kelly Daniel,
Popat Ketul,
Easley Jeremiah,
Palmer Ross,
Haut Donahue Tammy L.
Publication year - 2019
Publication title -
journal of orthopaedic research®
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.041
H-Index - 155
eISSN - 1554-527X
pISSN - 0736-0266
DOI - 10.1002/jor.24183
Subject(s) - anterior cruciate ligament , scaffold , soft tissue , biomedical engineering , ligament , tissue engineering , stifle joint , medicine , materials science , anatomy , cruciate ligament , surgery
The anterior cruciate ligament (ACL) acts to stabilize the knee and prevent excessive motion of the tibia relative to the femur. Tears of the ACL are common and can result in pain and damage to surrounding tissues. Thus a torn ACL is often surgically replaced with an autograft or allograft material. Drawbacks to clinically available ACL grafts motivate the development of a tissue engineered ACL replacement. Our group has previously developed a polycaprolactone electrospun scaffold that mimics the hierarchical structure of the ACL. The goal of this study was to investigate the mechanical properties of the electrospun scaffold as an ACL replacement. Scaffold mechanical properties were assessed prior to implantation via stress relaxation and pull to failure testing. Following in vitro characterization, electrospun scaffolds and soft tissue grafts were implanted into ovine cadaver stifle joints as ACL replacements. Stifle joints with ACL replacements were tested via a simulated anterior drawer test as well as in situ stress relaxation and pull to failure tests and compared to stifle joints with the native ACL intact. Prior to implantation the scaffold matched the native ovine ACL well in the range of functional strains as evidenced by stress relaxation measures and the toe region stiffness. After implantation the scaffold was more similar to the native ACL than the soft tissue graft, particularly when it came to reducing joint laxity and matching stress relaxation measures. These results demonstrate that the electrospun scaffold has the potential to be a suitable material for ACL replacement. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:421–430, 2019.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here