z-logo
Premium
High concentration and bioactivity of vancomycin and aztreonam eluted from Simplex™ cement spacers in two‐stage revision of infected hip implants: A study of 46 patients at an average follow‐up of 107 days
Author(s) -
Hsieh PangHsin,
Chang YuHan,
Chen ShihHao,
Ueng Steve W.N.,
Shih ChunHsiung
Publication year - 2006
Publication title -
journal of orthopaedic research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.041
H-Index - 155
eISSN - 1554-527X
pISSN - 0736-0266
DOI - 10.1002/jor.20214
Subject(s) - aztreonam , vancomycin , elution , stage (stratigraphy) , cement , medicine , materials science , chemistry , microbiology and biotechnology , chromatography , antibiotics , composite material , biology , bacteria , genetics , antibiotic resistance , imipenem , staphylococcus aureus , paleontology
This study investigated the release of antibiotics in vivo, from an articulating polymethylmethacrylate (PMMA) spacer used in two‐stage revision arthroplasty of infected hip implants. Forty‐six patients who underwent two‐stage revision hip arthroplasty for infections were managed with an interim PMMA spacer loaded with a high dose of vancomycin and aztreonam. Serum and aliquots of drainage collected after the first‐stage surgery, and joint fluid obtained at the time of the second‐stage surgery were analyzed for antibiotic concentrations by high performance liquid chromatography and bioactivity by tube dilution bioassay. Following implantation, the highest levels of antibiotics were measured in aliquots of drainage on the first day (vancomycin: 1538.0 ± 243.6 µg/mL; aztreonam: 1003.5 ± 323.5 µg/mL), decreasing to 571.9 ± 169.4 µg/mL for vancomycin and 313.6 ± 88.3 µg/mL for aztreonam after 7 days. Antibiotic concentrations in serum were very low (vancomycin: 0.58 ± 0.2 µg/mL, range: 0.1–1.6 µg/mL; aztreonam: 0.46 ± 0.3 µg/mL, range: 0.1–0.9 µg/mL at 24 h) and there was no systemic adverse effect. At a mean 107 days after the first‐stage surgery, the concentrations of antibiotics in joint fluid were well above the minimal inhibitory concentration of most common microorganisms. The released antibiotics were bioactive against the test organisms. Based on the observed results, we confirmed the safety and effectiveness of in vivo drug delivery from antibiotic‐impregnated PMMA hip spacers. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 24:1615–1621, 2006

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here