Subject(s) - ultimate tensile strength , materials science , ligament , composite material , interosseous membrane , ulna , forearm , anatomy , medicine
The interosseous membrane is a structure deep in the forearm that joins the radius and the ulna. It is made up of membranous and ligamentous regions. Two main ligamentous structures have been described: a prominent central fiber group, the “central band,” and a smaller proximal fibrous band, the “oblique cord.” Many authors believe that the central band plays a biomechanical role in the normal and fractured forearm and that it may function much like a ligament. The objective of this study was to determine the tensile properties of the central band. Eighteen fresh frozen forearms from cadavers (45–70 years of age, both sexes) were used. A fiber bundle of the central band was subjected to a uniaxial tensile test to failure in a materials testing machine, and its tensile properties were calculated. Stiffness, ultimate load, and energy absorbed to failure were expressed as a function of specimen width. The central band structure had a stiffness of 13.1 ± 3.0 N/mm per mm width and an ultimate load of 56.6 ± 15.1 N per mm width (mean ± SD). The tissue of the central band displayed a modulus of 608.1 ± 160.2 MPa, ultimate tensile strength of 45.1 ± 10.3 MPa, and strain at failure of 9.0 ± 2.0%. This study demonstrated that the central band is comprised of strong tissue. The material properties of the central band compare with those of patellar tendon: modulus is 120% and ultimate tensile strength is 84% that of patellar tendon. As a structure, the interosseous membrane is stiff and capable of bearing high loads. Although load distribution across the central band is unknown, a 1.7 cm wide, evenly loaded homogenous portion of the central band would possess a stiffness comparable with that of the anterior cruciate ligament. The results of this study provide a basis for future analyses of radioulnar stability and load transfer.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom