z-logo
Premium
Diagnostic accuracy of an automated chemiluminescent immunoassay for anti‐SARS‐CoV‐2 IgM and IgG antibodies: an Italian experience
Author(s) -
Infantino Maria,
Grossi Valentina,
Lari Barbara,
Bambi Riccardo,
Perri Alessandro,
Manneschi Matteo,
Terenzi Giovanni,
Liotti Irene,
Ciotta Giovanni,
Taddei Cristina,
Benucci Maurizio,
Casprini Patrizia,
Veneziani Francesca,
Fabbri Sergio,
Pompetti Adolfo,
Manfredi Mariangela
Publication year - 2020
Publication title -
journal of medical virology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.782
H-Index - 121
eISSN - 1096-9071
pISSN - 0146-6615
DOI - 10.1002/jmv.25932
Subject(s) - serology , antibody , virology , gold standard (test) , covid-19 , medicine , immunoassay , coronavirus , chemiluminescence , chemiluminescent immunoassay , immunoglobulin m , immunology , immunoglobulin g , disease , infectious disease (medical specialty) , chemistry , organic chemistry
A pandemic of coronavirus disease 2019 (COVID‐19) caused by severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) has been spreading throughout the world. Though molecular diagnostic tests are the gold standard for COVID‐19, serological testing is emerging as a potential surveillance tool, in addition to its complementary role in COVID‐19 diagnostics. Indubitably quantitative serological testing provides greater advantages than qualitative tests but today there is still little known about serological diagnostics and what the most appropriate role quantitative tests might play. Sixty‐one COVID‐19 patients and 64 patients from a control group were tested by iFlash1800 CLIA analyzer for anti‐SARS CoV‐2 antibodies IgM and IgG. All COVID‐19 patients were hospitalized in San Giovanni di Dio Hospital (Florence, Italy) and had a positive oro/nasopharyngeal swab reverse‐transcription polymerase chain reaction result. The highest sensitivity with a very good specificity performance was reached at a cutoff value of 10.0 AU/mL for IgM and of 7.1 for IgG antibodies, hence near to the manufacturer's cutoff values of 10 AU/mL for both isotypes. The receiver operating characteristic curves showed area under the curve values of 0.918 and 0.980 for anti‐SARS CoV‐2 antibodies IgM and IgG, respectively. iFlash1800 CLIA analyzer has shown highly accurate results for the anti‐SARS‐CoV‐2 antibodies profile and can be considered an excellent tool for COVID‐19 diagnostics.