z-logo
Premium
Measurement of bile acid CoA esters by high‐performance liquid chromatography–electrospray ionisation tandem mass spectrometry (HPLC–ESI‐MS/MS)
Author(s) -
GanSchreier H.,
Okun J. G.,
Kohlmueller D.,
Langhans C.D.,
Peters V.,
ten Brink H. J.,
Verhoeven N. M.,
Jakobs C.,
Voelkl A.,
Hoffmann G. F.
Publication year - 2005
Publication title -
journal of mass spectrometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.475
H-Index - 121
eISSN - 1096-9888
pISSN - 1076-5174
DOI - 10.1002/jms.864
Subject(s) - chemistry , chromatography , high performance liquid chromatography , electrospray ionization , tandem mass spectrometry , mass spectrometry , electrospray , cholic acid , liquid chromatography–mass spectrometry , bile acid , solid phase extraction , detection limit , extraction (chemistry) , biochemistry
Abstract The novel and rapid assay presented here combines high‐performance liquid chromatography and electrospray ionisation tandem mass spectrometry (HPLC‐ESI‐MS/MS) to directly measure and quantify the CoA esters of 3α,7α,12α‐trihydroxy‐ and 3α,7α‐dihydroxy‐5β‐cholestan‐26‐oic acid (THCA and DHCA). The latter are converted inside peroxisomes to the primary bile acids, cholic and chenodeoxycholic acids, respectively. Prior to MS/MS, esters were separated by reversed‐phase HPLC on a C 18 column using an isocratic mobile phase (acetonitrile/water/2‐propanol) and subsequently detected by multiple reaction monitoring. For quantification, the CoA ester of deuterium‐labelled 3α,7α,12α‐trihydroxy‐5β‐cholan‐24‐oic acid ( d 4 ‐CA) was used as internal standard. To complete an assay took less than 8 min. To verify the validity of the assay, the effect of peroxisomal proteins on the efficacy of extraction of the CoA esters was tested. To this end, variable amounts of the CoA esters were spiked with a fixed amount of either intact peroxisomes or peroxisomal matrix proteins and then extracted using a solid‐phase extraction system. The CoA esters could be reproducibly recovered in the range of 0.1–4 µmol l −1 (linear correlation coefficient R 2 > 0.99), with a detection limit of 0.1 µmol l −1 . In summary, electrospray ionization tandem mass spectrometry combined with HPLC as described here proved to be a rapid and versatile technique for the determination of bile acid CoA esters in a mixture with peroxisomal proteins. This suggests this technique to become a valuable tool in studies dealing with the multi‐step biosynthesis of bile acids and its disturbances in disorders like the Zellweger syndrome. Copyright © 2005 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here