An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three‐dimensional printed anatomical models constructed by fused deposition modelling
Author(s) -
Searle Ben,
Starkey Deborah
Publication year - 2020
Publication title -
journal of medical radiation sciences
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.484
H-Index - 18
eISSN - 2051-3909
pISSN - 2051-3895
DOI - 10.1002/jmrs.382
Subject(s) - replication (statistics) , imaging phantom , calipers , scanner , 3d printed , standard deviation , computer science , computed tomography , fused deposition modeling , software , mean squared error , tomography , biomedical engineering , nuclear medicine , materials science , mathematics , artificial intelligence , geometry , 3d printing , statistics , optics , physics , medicine , radiology , composite material , programming language
Three‐dimensional (3D) printed models can be constructed utilising computed tomography (CT) data. This project aimed to determine the effect of changing the slice reconstruction interval (SRI) on the spatial replication accuracy of 3D‐printed anatomical models constructed by fused deposition modelling (FDM). Methods Three bovine vertebrae and an imaging phantom were imaged using a CT scanner. The Queensland State Government’s Animal Care and Protection Act 2001 did not apply as no animals were harmed to carry out scientific activity. The data were reconstructed into SRIs of 0.1, 0.3, 0.5 and 1 mm and processed by software before 3D printing. Specimens and printed models were measured with calipers to calculate mean absolute error prior to statistical analysis. Results Mean absolute error from the original models for the 0.1, 0.3, 0.5 and 1 mm 3D‐printed models was 0.592 ± 0.396 mm, 0.598 ± 0.479 mm, 0.712 ± 0.498 mm and 0.933 ± 0.457 mm, respectively. Paired t‐tests ( P  < 0.05) indicated a statistically significant difference between all original specimens and corresponding 3D‐printed models except the 0.1 mm vertebrae 2 ( P  = 0.061), 0.3 mm phantom 1 ( P  = 0.209) and 0.3 mm vertebrae 2 ( P  = 0.097). Conclusion This study demonstrated that changing the SRI influences the spatial replication accuracy of 3D‐printed models constructed by FDM. Matching the SRI to the primary spatial resolution limiting factor of acquisition slice width or printer capabilities optimises replication accuracy.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here