Measuring tissue sodium concentration: Cross‐vendor repeatability and reproducibility of 23 Na‐MRI across two sites
Author(s) -
Riemer Frank,
McHugh Damien,
Zaccagna Fulvio,
Lewis Daniel,
McLean Mary A.,
Graves Martin J.,
Gilbert Fiona J.,
Parker Geoff J.M.,
Gallagher Ferdia A.
Publication year - 2019
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.26705
Subject(s) - reproducibility , repeatability , nuclear medicine , medicine , white matter , magnetic resonance imaging , chemistry , radiology , chromatography
Background Sodium MRI ( 23 Na‐MRI)‐derived biomarkers such as total sodium concentration (TSC) have the potential to provide information on tumor cellularity and the changes in tumor microstructure that occur following therapy. Purpose To evaluate the repeatability and reproducibility of TSC measurements in the brains of healthy volunteers, providing evidence for the technical validation of 23 Na‐MRI‐derived biomarkers. Study Type Prospective multicenter study. Subjects Eleven volunteers (32 ± 6 years; eight males, three females) were scanned twice at each of two sites. Field Strength/Sequence Comparable 3D‐cones 23 Na‐MRI ultrashort echo time acquisitions at 3T. Assessment TSC values, quantified from calibration phantoms placed in the field of view, were obtained from white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF), based on automated segmentation of coregistered 1 H T 1 ‐weighted images and hand‐drawn regions of interest by two readers. Statistical Tests Coefficients of variation (CoVs) from mean TSC values were used to assess intrasite repeatability and intersite reproducibility. Results Mean GM TSC concentrations (52.1 ± 7.1 mM) were ∼20% higher than for WM (41.8 ± 6.7 mM). Measurements were highly repeatable at both sites with mean scan–rescan CoVs between volunteers and regions of 2% and 4%, respectively. Mean intersite reproducibility CoVs were 3%, 3%, and 6% for WM, GM, and CSF, respectively. Data Conclusion These results demonstrate technical validation of sodium MRI‐derived biomarkers in healthy volunteers. We also show that comparable 23 Na imaging of the brain can be implemented across different sites and scanners with excellent repeatability and reproducibility. Level of Evidence : 1 Technical Efficacy : Stage 2 J. Magn. Reson. Imaging 2019;50:1278–1284.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here