Premium
MR spectroscopy of breast cancer for assessing early treatment response: Results from the ACRIN 6657 MRS trial
Author(s) -
Bolan Patrick J.,
Kim Eunhee,
Herman Benjamin A.,
Newstead Gillian M.,
Rosen Mark A.,
Schnall Mitchell D.,
Pisano Etta D.,
Weatherall Paul T.,
Morris Elizabeth A.,
Lehman Constance D.,
Garwood Michael,
Nelson Michael T.,
Yee Douglas,
Polin Sandra M.,
Esserman Laura J.,
Gatsonis Constantine A.,
Metzger Gregory J.,
Newitt David C.,
Partridge Savannah C.,
Hylton Nola M.
Publication year - 2017
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.25560
Subject(s) - medicine , breast cancer , receiver operating characteristic , confidence interval , logistic regression , health insurance portability and accountability act , regimen , area under the curve , cancer , oncology , medical physics , health care , economics , economic growth
Purpose To estimate the accuracy of predicting response to neoadjuvant chemotherapy (NACT) in patients with locally advanced breast cancer using MR spectroscopy (MRS) measurements made very early in treatment. Materials and Methods This prospective Health Insurance Portability and Accountability Act (HIPAA)–compliant protocol was approved by the American College of Radiology and local‐site institutional review boards. One hundred nineteen women with invasive breast cancer of ≥3 cm undergoing NACT were enrolled between September 2007 and April 2010. MRS measurements of the concentration of choline‐containing compounds ([tCho]) were performed before the first chemotherapy regimen (time point 1, TP1) and 20–96 h after the first cycle of treatment (TP2). The change in [tCho] was assessed for its ability to predict pathologic complete response (pCR) and radiologic response using the area under the receiver operating characteristic curve (AUC) and logistic regression models. Results Of the 119 subjects enrolled, only 29 cases (24%) with eight pCRs provided usable data for the primary analysis. Technical challenges in acquiring quantitative MRS data in a multi‐site trial setting limited the capture of usable data. In this limited data set, the decrease in tCho from TP1 to TP2 had poor ability to predict either pCR (AUC = 0.53, 95% confidence interval [CI]: 0.27–0.79) or radiologic response (AUC = 0.51, 95% CI: 0.27–0.75). Conclusion The technical difficulty of acquiring quantitative MRS data in a multi‐site clinical trial setting led to a low yield of analyzable data, which was insufficient to accurately measure the ability of early MRS measurements to predict response to NACT. Level of Evidence: 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:290–302