z-logo
Premium
Ultrashort echo time MRI biomarkers of asthma
Author(s) -
Sheikh Khadija,
Guo Fumin,
Capaldi Dante P.I.,
Ouriadov Alexei,
Eddy Rachel L.,
Svenningsen Sarah,
Parraga Grace
Publication year - 2017
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.25503
Subject(s) - medicine , expiration , radiodensity , nuclear medicine , air trapping , lung , asthma , ventilation (architecture) , magnetic resonance imaging , lung volumes , radiology , pulmonary function testing , respiratory system , radiography , mechanical engineering , engineering
Purpose To develop and assess ultrashort echo‐time (UTE) magnetic resonance imaging (MRI) biomarkers of lung function in asthma patients. Materials and Methods Thirty participants including 13 healthy volunteers and 17 asthmatics provided written informed consent to UTE and pulmonary function tests in addition to hyperpolarized‐noble‐gas 3T MRI and computed tomography (CT) for asthmatics only. The difference in MRI signal‐intensity (SI) across four lung volumes (full‐expiration, functional‐residual‐capacity [FRC], FRC+1L, and full‐inspiration) was determined on a voxel‐by‐voxel basis to generate dynamic proton‐density (DPD) maps. MRI ventilation‐defect‐percent (VDP), UTE SI, and DPD values as well as CT radiodensity were determined for whole lung and individual lobes. Results Mean SI at full‐expiration ( P < 0.01), FRC ( P < 0.05), and DPD ( P < 0.01) were greater in healthy volunteers compared to asthmatics. In asthmatics, UTE SI at full‐expiration and DPD were correlated with FEV 1 /FVC (SI r  = 0.73/ P  = 0.002; DPD r  = 0.75/ P  = 0.003), RV/TLC (SI r  = –0.57/ P  = 0.02), or RV (DPD r  = –0.62/ P  = 0.02), CT radiodensity (SI r  = 0.83/ P  = 0.006; DPD r  = 0.71/ P  = 0.01), and lobar VDP (SI r s  = –0.33/ P  = 0.02; DPD r s  = –0.47/ P  = 0.01). Conclusion In patients with asthma, UTE SI and dynamic proton‐density were related to pulmonary function measurements, whole lung and lobar VDP, as well as CT radiodensity. Thus, UTE MRI biomarkers may reflect ventilation heterogeneity and/or gas‐trapping in asthmatics using conventional equipment, making this approach potentially amenable for clinical use. Level of Evidence: 2 J. Magn. Reson. Imaging 2017;45:1204–1215

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here