z-logo
Premium
Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol‐enhanced 4D flow MRI
Author(s) -
Hanneman Kate,
Kino Aya,
Cheng Joseph Y.,
Alley Marcus T.,
Vasanawala Shreyas S.
Publication year - 2016
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.25180
Subject(s) - steady state free precession imaging , medicine , intraclass correlation , limits of agreement , reproducibility , nuclear medicine , ejection fraction , cardiology , magnetic resonance imaging , radiology , heart failure , mathematics , statistics
Purpose To compare the precision and interobserver agreement of ventricular volume, function, and mass quantification by 3D time‐resolved (4D) flow MRI relative to cine steady‐state free precession (SSFP). Materials and Methods With Institutional Research Board approval, informed consent, and HIPAA compliance, 22 consecutive patients with congenital heart disease (CHD) (10 males, 6.4 ± 4.8 years) referred for 3T ferumoxytol‐enhanced cardiac MRI were prospectively recruited. Complete ventricular coverage with standard 2D short‐axis cine SSFP and whole chest coverage with axial 4D flow were obtained. Two blinded radiologists independently segmented images for left ventricular (LV) and right ventricular (RV) myocardium at end systole (ES) and end diastole (ED). Statistical analysis included linear regression, analysis of variance (ANOVA), Bland–Altman (BA) analysis, and intraclass correlation (ICC). Results Significant positive correlations were found between 4D flow and SSFP for ventricular volumes ( r  = 0.808–0.972, P < 0.001), ejection fraction (EF) ( r  = 0.900–928, P < 0.001), and mass ( r  = 0.884–0.934, P < 0.001). BA relative limits of agreement for both ventricles were between –52% to 34% for volumes, –29% to 27% for EF, and –41% to 48% for mass, with wider limits of agreement for the RV compared to the LV. There was no significant difference between techniques with respect to mean square difference of ED‐ES mass for either LV (F = 2.05, P  = 0.159) or RV (F = 0.625, P  = 0.434). Interobserver agreement was moderate to good with both 4D flow (ICC 0.523–0.993) and SSFP (ICC 0.619–0.982), with overlapping confidence intervals. Conclusion Quantification of ventricular volume, function, and mass can be accomplished with 4D flow MRI with precision and interobserver agreement comparable to that of cine SSFP. J. Magn. Reson. Imaging 2016;44:383–392.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here