Premium
Comparison of 0.5M gadoterate and 1.0M gadobutrol in peripheral MRA: A prospective, single‐center, randomized, crossover, double‐blind study
Author(s) -
Haneder Stefan,
Attenberger Ulrike I.,
Schoenberg Stefan O.,
Loewe Christian,
Arnaiz Javier,
Michaely Henrik J.
Publication year - 2012
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.23760
Subject(s) - gadobutrol , double blind , peripheral , crossover study , medicine , physics , nuclear medicine , radiology , magnetic resonance imaging , pathology , placebo , alternative medicine
Purpose: To evaluate the diagnostic efficacy of macrocyclic paramagnetic gadolinium (Gd) chelates gadoterate (0.5 mmol/mL) and gadobutrol (1.0 mmol/mL) for the diagnosis of clinically significant abdominal/lower limb arterial diseases at 3.0T. Materials and Methods: This study was conducted as a prospective, single‐center, randomized, double‐blind, intraindividual study comparing single dose (0.1 mmol/kg) gadoterate enhanced‐MRA (magnetic resonance angiography) with gadobutrol enhanced‐MRA at 3.0T for their diagnostic potential in patients with peripheral artery disease. A total of 20 patients were included in this trial. Results: Fourteen patients were eligible for the final efficacy analysis. The overall image quality (excellent/more than adequate) was better rated with gadoterate than with gadobutrol (100% vs. 78.6%, 100% vs. 92.9%, 100% vs. 85.7%, 100% vs. 85.7% for readers 1, 2, 3, 4, respectively). Diagnostic confidence was rated high/excellent in 100% (readers 1, 2, and 3) and 92.9% (reader 4) with gadoterate compared to 92.9% (readers 1 and 2) and 85.7% (readers 3 and 4) with gadobutrol. Higher signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) values were obtained for gadobutrol compared to gadoterate (26.1/23.4, P = 0.01, and 22.7/20.2, P = 0.01). For the secondary criteria, no differences between groups were reported. No adverse events were reported. Conclusion: Gadobutrol yielded significantly higher SNR/CNR while gadoterate was better rated in terms of overall image quality and diagnostic confidence ( P > 0.05). J. Magn. Reson. Imaging 2012;36:1213–1221. © 2012 Wiley Periodicals, Inc.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom