z-logo
Premium
Detection of hepatocellular carcinoma (HCC) using super paramagnetic iron oxide (SPIO)‐enhanced MRI: Added value of diffusion‐weighted imaging (DWI)
Author(s) -
Nishie Akihiro,
Tajima Tsuyoshi,
Ishigami Kousei,
Ushijima Yasuhiro,
Okamoto Daisuke,
Hirakawa Masakazu,
Nishihara Yunosuke,
Taketomi Akinobu,
Hatakenaka Masamitsu,
Irie Hiroyuki,
Yoshimitsu Kengo,
Honda Hiroshi
Publication year - 2010
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.22059
Subject(s) - medicine , hepatocellular carcinoma , magnetic resonance imaging , diffusion mri , nuclear medicine , receiver operating characteristic , fast spin echo , radiology
Purpose: To evaluate whether diffusion‐weighted imaging (DWI) improves the detection of hepatocellular carcinoma (HCC) on super paramagnetic iron oxide (SPIO)‐enhanced MRI. Materials and Methods: This retrospective study group consisted of 30 patients with 50 HCC nodules who underwent MRI at 1.5 Tesla. Two combined MR sequence sets were compared for detecting HCC: SPIO‐enhanced MRI (axial T2‐weighted fast spin‐echo (FSE) and T1‐/T2*‐weighted fast field echo (FFE) scanned before and after administration of ferucarbotran) and SPIO‐enhanced MRI + DWI (SPIO‐enhanced MRI with axial DWI scanned before and after administration of ferucarbotran). Three blinded readers independently reviewed for the presence of HCC on a segment‐by‐segment basis using a four‐point confidence scale. The performance of the two combined MR sequence sets was evaluated using receiver operating characteristic (ROC) analysis. Results: The average area under the ROC curve (Az) of the three readers for the SPIO‐enhanced MRI + DWI set (0.870 ± 0.046) was significantly higher that that for the SPIO‐enhanced MRI set (0.820 ± 0.055) ( P = .025). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detection of HCC were 66.0%, 98.0%, 90.0%, and 91.4%, respectively, for the SPIO‐enhanced MRI set, and 70.0%, 98.6%, 92.9%, and 92.4%, respectively, for the SPIO‐enhanced MRI + DWI set. Conclusion: The SPIO‐enhanced MRI + DWI set outperformed the SPIO‐enhanced MRI set for depicting HCC. J. Magn. Reson. Imaging 2010; 31: 373–382. © 2010 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom