Reader and platform reproducibility for quantitative assessment of carotid atherosclerotic plaque using 1.5T Siemens, Philips, and General Electric scanners
Author(s) -
Saam Tobias,
Hatsukami Thomas S.,
Yarnykh Vasily L.,
Hayes Cecil E.,
Underhill Hunter,
Chu Baocheng,
Takaya Norihide,
Cai Jianming,
Kerwin William S.,
Xu Dongxiang,
Polissar Nayak L.,
Neradilek B.,
Hamar Wendy K.,
Maki Jeffrey,
Shaw Dennis W.,
Buck Robert J.,
Wyman Brad,
Yuan Chun
Publication year - 2007
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.21004
Subject(s) - reproducibility , scanner , siemens , nuclear medicine , medicine , biomedical engineering , coefficient of variation , radiology , computer science , mathematics , physics , artificial intelligence , statistics , quantum mechanics
Purpose To evaluate the platform and reader reproducibility of quantitative carotid plaque measurements. Materials and Methods A total of 32 individuals with ≥15% carotid stenosis by duplex ultrasound were each imaged once by a 1.5T General Electric (GE) whole body scanner and twice by either a 1.5T Philips scanner or a 1.5T Siemens scanner. A standardized multisequence protocol and identical phased‐array carotid coils were used. Expert readers, blinded to subject information, scanner type, and time point, measured the lumen, wall, and total vessel areas and determined the modified American Heart Association lesion type (AHA‐LT) on the cross‐sectional images. Results AHA‐LT was consistently identified across the same (κ = 0.75) and different scan platforms (κ = 0.75). Furthermore, scan‐rescan coefficients of variation (CV) of wall area measurements on Siemens and Philips scanners ranged from 6.3% to 7.5%. However, wall area measurements differed between Philips and GE ( P = 0.003) and between Siemens and GE ( P = 0.05). In general, intrareader reproducibility was higher than interreader reproducibility for AHA‐LT identification as well as for quantitative measurements. Conclusion All three scanners produced images that allowed AHA‐LT to be consistently identified. Reproducibility of quantitative measurements by Siemens and Philips scanners were comparable to previous studies using 1.5T GE scanners. However, bias was introduced with each scanner and the use of different readers substantially increased variability. We therefore recommend using the same platform and the same reader for scans of individual subjects undergoing serial assessment of carotid atherosclerosis. J. Magn. Reson. Imaging 2007. © 2007 Wiley‐Liss, Inc.