Premium
Spatial variation in cartilage T2 of the knee
Author(s) -
Smith Harvey E.,
Mosher Timothy J.,
Dardzinski Bernard J.,
Collins Belinda G.,
Collins Christopher M.,
Yang Qing X.,
Schmithorst Vincent J.,
Smith Michael B.
Publication year - 2001
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/jmri.1150
Subject(s) - cartilage , knee cartilage , patella , articular cartilage , knee joint , osteoarthritis , medicine , tibia , anatomy , in vivo , biomedical engineering , pathology , biology , surgery , alternative medicine , microbiology and biotechnology
Technical limitations imposed by resolution and B1 homogeneity have thus far limited quantitative in vivo T2 mapping of cartilage to the patella. The purpose of this study is to develop T2 mapping of the femoral/tibial joint and assess regional variability of cartilage T2 in the knee. Quantitative in vivo T2 mapping of the knee was performed on 15 asymptomatic adults (age, 22–44) using a 3T MR scanner. There is a consistent pattern of spatial variation in cartilage T2 with longer values near the articular surface. The greatest variation occurs in the patella, where T2 increases from 45.3 ± 2.5 msec at a normalized distance of 0.33–67 ± 5.5 msec at a distance of 1.0. These results demonstrate feasibility of performing in vivo T2 mapping of femoral tibial cartilage. Except for the superficial 15% where T2 values are lower, the spatial variation in T2 of femoral and tibial cartilage is similar to patellar cartilage. J. Magn. Reson. Imaging 2001;14:50–55. © 2001 Wiley‐Liss, Inc.