Prostate‐specific membrane antigen (PSMA)‐targeted imaging and therapy of prostate cancer using theranostic pairs is rapidly changing clinical practice. To facilitate clinical trials, fully automated procedures for the radiosyntheses of [ 68 Ga]Ga‐PSMA‐11 and [ 177 Lu]Lu‐PSMA‐617 were developed from commercially available precursors using the cassette based iPHASE MultiSyn module. Formulated and sterile radiopharmaceuticals were obtained in 76 ± 3% ( n = 20) and 91 ± 4% ( n = 15) radiochemical yields after 17 and 20 min, respectively. Radiochemical purity was always >95% and molar activities exceeded 792 ± 100 and 88 ± 6 GBq/μmol, respectively. Quality control showed conformity with all relevant release criteria and radiopharmaceuticals were used in the clinic.