z-logo
Premium
Systematic Review of Physiologic Monitor Alarm Characteristics and Pragmatic Interventions to Reduce Alarm Frequency
Author(s) -
Paine Christine Weirich,
Goel Veena V.,
Ely Elizabeth,
Stave Christopher D.,
Stemler Shan,
Zander Miriam,
Bonafide Christopher P.
Publication year - 2016
Publication title -
journal of hospital medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.128
H-Index - 65
eISSN - 1553-5606
pISSN - 1553-5592
DOI - 10.1002/jhm.2520
Subject(s) - alarm , psychological intervention , medicine , data extraction , medline , observational study , scopus , medical emergency , nursing , political science , materials science , law , composite material , pathology
BACKGROUND Alarm fatigue from frequent nonactionable physiologic monitor alarms is frequently named as a threat to patient safety. PURPOSE To critically examine the available literature relevant to alarm fatigue. DATA SOURCES Articles published in English, Spanish, or French between January 1980 and April 2015 indexed in PubMed, Cumulative Index to Nursing and Allied Health Literature, Scopus, Cochrane Library, Google Scholar, and ClinicalTrials.gov . STUDY SELECTION Articles focused on hospital physiologic monitor alarms addressing any of the following: (1) the proportion of alarms that are actionable, (2) the relationship between alarm exposure and nurse response time, and (3) the effectiveness of interventions in reducing alarm frequency. DATA EXTRACTION We extracted data on setting, collection methods, proportion of alarms determined to be actionable, nurse response time, and associations between interventions and alarm rates. DATA SYNTHESIS Our search produced 24 observational studies focused on alarm characteristics and response time and 8 studies evaluating interventions. Actionable alarm proportion ranged from <1% to 36% across a range of hospital settings. Two studies showed relationships between high alarm exposure and longer nurse response time. Most intervention studies included multiple components implemented simultaneously. Although studies varied widely, and many had high risk of bias, promising but still unproven interventions include widening alarm parameters, instituting alarm delays, and using disposable electrocardiographic wires or frequently changed electrocardiographic electrodes. CONCLUSIONS Physiologic monitor alarms are commonly nonactionable, and evidence supporting the concept of alarm fatigue is emerging. Several interventions have the potential to reduce alarms safely, but more rigorously designed studies with attention to possible unintended consequences are needed. Journal of Hospital Medicine 2016;11:136–144. © 2015 Society of Hospital Medicine

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here