z-logo
open-access-imgOpen Access
Gastroesophageal varices evaluation using spleen‐dedicated stiffness measurement by vibration‐controlled transient elastography
Author(s) -
Nagai Koki,
Ogawa Yuji,
Kobayashi Takashi,
Iwaki Michihiro,
Nogami Asako,
Honda Yasushi,
Kessoku Takaomi,
Saigusa Yusuke,
Imajo Kento,
Yoneda Masato,
Kirikoshi Hiroyuki,
Komatsu Tatsuji,
Saito Satoru,
Nakajima Atsushi
Publication year - 2022
Publication title -
jgh open
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.546
H-Index - 8
ISSN - 2397-9070
DOI - 10.1002/jgh3.12689
Subject(s) - transient elastography , medicine , receiver operating characteristic , elastography , gastric varices , varices , portal hypertension , esophagogastroduodenoscopy , gastroenterology , nuclear medicine , endoscopy , radiology , ultrasound , cirrhosis , liver fibrosis
Abstract Background and Aim Liver stiffness measurement (LSM) and spleen stiffness measurement (SSM@50 Hz) using standard vibration‐controlled transient elastography (VCTE) have been studied as a noninvasive test for screening of gastroesophageal varices (GEV) in chronic liver disease (CLD). Recently, a novel spleen‐dedicated VCTE (SSM@100 Hz) has been developed. We evaluated the diagnostic performance of SSM@100 Hz, SSM@50 Hz, LSM, and other noninvasive tests using esophagogastroduodenoscopy (EGD) as the reference as well as the correlation with hepatic venous pressure gradient (HVPG). Methods A total of 123 patients with CLD enrolled in this cross‐sectional study. SSM@100 Hz, SSM@50 Hz, and LSM were determined by VCTE. EGD and HVPG were performed within 12 weeks before or after VCTE. Results GEV were present in 60 patients. Failure or suboptimal SSM were fewer at 100 Hz (4.0%) than at 50 Hz (17.7%). All SSM values obtained at 100 Hz were lower than the 100 kPa ceiling threshold, but 10 patients reached the 75 kPa ceiling threshold for SSM@50 Hz. SSM@100 Hz was most accurate (area under the receiver operating characteristic [AUROC] = 0.944) for the diagnosis of GEV compared to SSM@50 Hz, LSM, and scoring systems. AUROC of SSM@100 Hz for diagnosis of high‐bleeding risk varices (HRV) was 0.941, which was significantly higher than that of SSM@50 Hz (AUROC = 0.842, P  = 0.002). SSM@100 Hz showed higher specificity (82.0%) for diagnosis of HRV than SSM@50 Hz (specificity = 67.1%). SSM@100 Hz was significantly correlated with HVPG ( r  = 0.71, P  < 0.001). Conclusions The novel spleen‐dedicated VCTE examination can be used for noninvasive assessment of GEV and HVPG in CLD. Japan Registry of Clinical Trials Registry No. jRCTs032200119.