Premium
Pseudoaneurysm of the genicular artery after wound closure using a skin stapler in a child
Author(s) -
Gürses Cemil,
Temeloğlu A. Eda Parlak,
Tuna Yeliz,
Erol Bekir,
Köroğlu Mert
Publication year - 2013
Publication title -
journal of clinical ultrasound
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.272
H-Index - 61
eISSN - 1097-0096
pISSN - 0091-2751
DOI - 10.1002/jcu.21941
Subject(s) - medicine , pseudoaneurysm , surgery , ultrasound , complication , anterior tibial artery , humerus , radiology , artery
A 9‐year‐old child with a left humerus fracture also had minor skin cuts on the right knee, which were closed with a skin stapler. After 1 week, a medial superior genicular artery pseudoaneurysm developed, which was treated by ultrasound‐guided compression. This case illustrates a unique complication of the use of a skin stapler device.© 2012 Wiley Periodicals, Inc. J Clin Ultrasound, 41:316–318, 2013