z-logo
Premium
Evaluation of severe transplant renal artery stenosis with Doppler sonography
Author(s) -
Li Jianchu,
Ji Zhigang,
Cai Sheng,
Jiang Yuxin,
Dai Qing,
Zhang Jinxi
Publication year - 2005
Publication title -
journal of clinical ultrasound
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.272
H-Index - 61
eISSN - 1097-0096
pISSN - 0091-2751
DOI - 10.1002/jcu.20129
Subject(s) - medicine , renal artery , anastomosis , stenosis , renal artery stenosis , radiology , external iliac artery , artery , cardiology , kidney , surgery
Purpose . To evaluate and determine Doppler criteria for predicting a severe transplant renal artery stenosis (80%–99% diameter reduction) and to compare the Doppler findings in patients with end‐to‐end and end‐to‐side anastomosis.Methods . We performed Doppler sonography on 16 consecutive patients with transplant renal artery stenosis (TRAS) confirmed by digital subtraction arteriography (DSA). Fourteen patients had end‐to‐end anastomosis, and 2 had end‐to‐side anastomosis. Eleven patients were re‐evaluated with color Doppler sonography within 4 days after intervention. Seven Doppler parameters, including the peak systolic velocity (PSV) in the renal, iliac and interlobar artery, Pre‐PSV ratio (the ratio of the PSV in the renal artery to that in the iliac artery), Post‐PSV ratio (the ratio of the PSV in the renal artery to that in the interlobar arterie, acceleration time and resistance index, were measured. In the patients with severe TRAS the measurements of these parameters were compared before and after successful intervention.Results . In the 16 patients with a single transplanted kidney, arteriography demonstrated 14 main renal arteries with severe stenosis, and 3 renal arteries with moderate stenosis. When using the cutoff values of Post‐PSV ratio >13, renal artery PSV >4 m/sec, acceleration time >0.06 second, and resistance index <0.5 for the detection of all 14 severe stenoses, the sensitivities were 100%, 71%, 93%, and 50%, respectively. For assessing all 14 severe stenoses and 12 severe stenoses of end‐to‐end anastomosis, the cutoff value of Pre‐PSV ratio >5 had sensitivities of 86% and 100%, respectively. Pre‐PSV ratios in severe stenoses of end‐to‐end anastomosis (range, 5.1–11.5) were significantly greater than those recorded in severe stenoses of end‐to‐side anastomosis (range, 2.8–3.1). Statistically significant differences before and after successful intervention were found for all 7 Doppler parameters in the 7 patients with severe stenosis.Conclusions . An 80%–99% diameter reduction of the renal artery can be diagnosed based on a Post‐PSV ratio >13 for patients with either end‐to‐end or end‐to‐side anastomosis. A Pre‐PSV ratio >5 for patients with end‐to‐end anastomosis and acceleration time >0.06 second are helpful in the diagnosis of severe TRAS. © 2005 Wiley Periodicals, Inc. J Clin Ultrasound 33 :261–269, 2005

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here