Evaluation of point‐of‐care testing device for anemia detection: A cross‐sectional method comparison study from Thailand
Author(s) -
Chantkran Wittawat,
Jamnarnwej Pitipat,
Sritanabutr Pipat,
Arnutti Pasra
Publication year - 2021
Publication title -
journal of clinical laboratory analysis
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.536
H-Index - 50
eISSN - 1098-2825
pISSN - 0887-8013
DOI - 10.1002/jcla.23976
Subject(s) - medicine , confidence interval , anemia , intraclass correlation , limits of agreement , cross sectional study , point of care testing , hematology analyzer , gastroenterology , nuclear medicine , pathology , clinical psychology , psychometrics
Background A comparison study is crucial before launching a new medical device; therefore, we compared the Mission Ultra Hb Testing System with the Sysmex XN‐3000 automated hematology analyzer in Thai adult males and non‐pregnant adult females. Methods Parallel studies were conducted using discarded venous K2‐ethylenediaminetetraacetic acid samples from participants requiring hematological investigations. According to the World Health Organization criteria, the participants were categorized as overall, anemia, and non‐anemia for analysis. Results Three hundred participants were included in this study. In all participants, near‐perfect correlation and agreement were observed between the two methods for Hb measurement ( r  = 0.963, p  < 0.001) with an interclass correlation coefficient (ICC) of 0.981 (95% confidence interval [CI]: 0.976–0.985) and Hct measurement ( r  = 0.941, p  < 0.001) with an ICC of 0.965 (95% CI: 0.956–0.972). The sensitivity and specificity of the device in detecting anemia were 86.2% (95% CI: 79.7–91.2) and 98.6% (95% CI: 95.2–99.8), respectively. The area under the curve was 0.976 (95% CI: 0.963–0.989). The device showed average biases of 0.76 g/dl (95% limits of agreement [LOA]: −1.03 to 2.54) for Hb measurement and −2.73% (95% LOA: −9.28 to 3.82) for Hct measurement in all participants. Conclusion Agreement between the Mission Ultra Hb Testing System and Sysmex XN‐3000 was observed. The device was excellent for detecting anemia. However, the essential evidence showing biases of the Hb and Hct measurements obtained from the device was revealed. Laboratory interpretation should be carefully performed, particularly at the near cut‐off values.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here