z-logo
Premium
Xylenol Orange‐Functionalized Halloysite Nanotubes as a Novel Adsorbent for Selective Solid‐phase Extraction and Determination of Trace Noble Elements
Author(s) -
Bao Amin,
Zheng Hong,
Liu Zeyu,
Huang Dongfang,
Li Bo,
Wang Shuya
Publication year - 2017
Publication title -
journal of the chinese chemical society
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.329
H-Index - 45
eISSN - 2192-6549
pISSN - 0009-4536
DOI - 10.1002/jccs.201700111
Subject(s) - chemistry , xylenol orange , adsorption , elution , solid phase extraction , sorbent , halloysite , certified reference materials , detection limit , chromatography , selective adsorption , selectivity , trace amounts , analytical chemistry (journal) , nuclear chemistry , catalysis , chemical engineering , medicine , biochemistry , alternative medicine , organic chemistry , pathology , engineering
A novel method using xylenol orange‐modified halloysite nanotubes as a solid‐phase sorbent has been developed for the simultaneous preconcentration and separation of trace Au( III ) and Pd( II ) prior to their determination by inductively coupled plasma‐atomic emission spectrometry ( ICP‐AES ). The experimental effects of pH , the amount of adsorbent, sample flow rate, sample volume, interfering ions, and the elution condition were investigated in detail. Au( III ) and Pd( II ) were retained on the column at pH 3, and eluted with 2.0  mL of 1.0 mol/L HCl + 2% CS ( NH 2 ) 2 solution. Common interfering ions did not have any impact on the adsorption, separation, and determination. An enrichment factor of 150 was obtained. The maximum adsorption capacities of the adsorbent were 41.63 and 47.82 mg/g for Au( III ) and Pd( II ), respectively, under the optimum conditions. By the definition of IUPAC , the detection limits (3 σ ) of this method for Au( III ) and Pd( II ) were 0.31 and 0.27 ng/ mL , and the relative standard deviations ( RSDs ) were 2.7 and 3.2%, respectively ( n  = 8). This newly developed method was verified by certified reference materials, and has been successfully applied to the determination of trace Au( III ) and Pd( II ) in mine samples with satisfactory results. It can be confidently predicted that the method can be used for the determination trace Au( III ) and Pd( II ) in other real samples because of its high selectivity, sensitivity, and reproducibility.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here