z-logo
Premium
Simultaneous Determination of Tin, Nickel, Lead, Cadmium and Mercury in Tobacco and Tobacco Additives by Microwave Digestion and RP‐HPLC Followed by On‐Line Column Enrichment
Author(s) -
Chen Zhangyu,
Yang GuangYu,
Wang Shuhua,
Li Ling,
Su Qingde
Publication year - 2004
Publication title -
journal of the chinese chemical society
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.329
H-Index - 45
eISSN - 2192-6549
pISSN - 0009-4536
DOI - 10.1002/jccs.200400012
Subject(s) - chemistry , cadmium , elution , acetic acid , nickel , metal ions in aqueous solution , chromatography , mercury (programming language) , high performance liquid chromatography , tin , chelation , detection limit , nuclear chemistry , metal , inorganic chemistry , biochemistry , organic chemistry , computer science , programming language
Abstract A new method for the simultaneous determination of five heavy metal ions, tin, nickel, lead, cadmium and mercury ions as metal‐tetra‐(2‐aminophenyl)‐porphyrin (T 2 APP) chelates was developed using reversed‐phase high performance liquid chromatography (RP‐HPLC) equipped with a photodiode array detector and combined with an on‐line enrichment technique. The tin, nickel, lead, cadmium and mercury ions were pre‐column derivatized with T 2 APP to form color chelates. The Sn‐T 2 APP, Ni‐T 2 APP, Hg‐T 2 APP, Cd‐T 2 ‐APP and Pb‐T 2 APP chelates can be absorbed onto the front of the enrichment column when they are injected into the injector and sent to the enrichment column [Waters Xterra™ RP 18 (5μ, 3.9 × 20 mm)] with a buffer solution of 0.05 mol/L pyrrolidine‐acetic acid (pH = 10.0) as mobile phase. After the enrichment had finished, by switching the six‐port switching valves, the retained chelates were back‐flushed by mobile phase and traveling towards the analytical column. These chelates separation on the analytical column [Waters Xterra™ RP 18 (5μ, 3.9 × 150 mm)] was satisfactory by gradient elution with methanol (containing 0.05 mol/L pyrrolidine‐acetic acid buffer salt, pH = 10.0) and acetone (containing 0.05 mol/L pyrrolidine‐acetic acid buffer salt, pH = 10.0) as mobile phase. The linearity range is 0.01˜120 μg/L for each metal ion. The detection limits (S/N = 3) of tin, nickel, lead, cadmium and mercury are 4.0 ng/L, 3.5 ng/L, 2.5 ng/L, 3.0 ng/L and 3.0 ng/L, respectively. This method was applied to the determination of tin, nickel, lead, cadmium and mercury ions in tobacco and tobacco additives with good results.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here