z-logo
Premium
Enhancement of the biocompatibility by surface nitriding of a low‐modulus titanium alloy for dental implant applications
Author(s) -
Bédouin Yvan,
Gordin DoinaMargareta,
PellenMussi Pascal,
Pérez Fabienne,
TricotDoleux Sylvie,
Vasilescu Cora,
Drob Silviu Iulian,
ChauvelLebret Dominique,
Gloriant Thierry
Publication year - 2019
Publication title -
journal of biomedical materials research part b: applied biomaterials
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.665
H-Index - 108
eISSN - 1552-4981
pISSN - 1552-4973
DOI - 10.1002/jbm.b.34240
Subject(s) - nitriding , materials science , biocompatibility , alloy , corrosion , titanium , titanium alloy , hardness , metallurgy , elastic modulus , surface modification , modulus , layer (electronics) , composite material , chemical engineering , engineering
To enhance their longevity, dental implants must be highly biocompatible and must have a low elastic modulus close to that of the bone. They must also possess a high superficial hardness and a high corrosion resistance. For these reasons, a recently developed low‐modulus Ti–27Nb alloy with nontoxic elements was treated by gas nitriding at high temperature in this study. A very thin nitrided layer of 0.5 μm in thickness followed by an enriched nitrogen zone was observed. Consequently, a very high hardness evaluated at about 1800 HV was obtained in surface, which represents an increase of 4–5 times the hardness of the non‐nitrided alloy. This superficial hardness was experimentally observed to decrease up to 800 nm in depth from the surface to the core. The low modulus of Ti–27Nb (evaluated at 55 GPa, which is twice lower than the commercially pure titanium) was not affected by the surface nitriding treatment. A better corrosion resistance was observed and a significant decrease in ion release rates for the nitrided alloy (ion release of 1.41 ng/cm 2 compared to the 163.58 ng/cm 2 obtained for the commercially pure titanium at pH = 7.48 in artificial Carter–Brugirard saliva). The cytocompatibility was not compromised and the cell viability performed on human osteoblasts, fibroblastic cells, and epithelial cells was enhanced on the nitrided surface in comparison with the non‐nitrided surface. These combined properties make the nitrided Ti–27Nb alloy a good candidate for dental implant applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1483–1490, 2019.