Cobalt deposition in mineralized bone tissue after metal‐on‐metal hip resurfacing: Quantitative μ‐X‐ray‐fluorescence analysis of implant material incorporation in periprosthetic tissue
Author(s) -
Hahn Michael,
Busse Björn,
Procop Mathias,
Zustin Jozef,
Amling Michael,
Katzer Alexander
Publication year - 2017
Publication title -
journal of biomedical materials research part b: applied biomaterials
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.665
H-Index - 108
eISSN - 1552-4981
pISSN - 1552-4973
DOI - 10.1002/jbm.b.33667
Subject(s) - periprosthetic , materials science , cobalt , hip resurfacing , implant , bone tissue , biomedical engineering , hip replacement , metal , polyethylene , prosthesis , soft tissue , femoral head , arthroplasty , metallurgy , surgery , composite material , medicine
Abstract Most resurfacing systems are manufactured from cobalt‐chromium alloys with metal‐on‐metal (MoM) bearing couples. Because the quantity of particulate metal and corrosion products which can be released into the periprosthetic milieu is greater in MoM bearings than in metal‐on‐polyethylene (MoP) bearings, it is hypothesized that the quantity and distribution of debris released by the MoM components induce a compositional change in the periprosthetic bone. To determine the validity of this claim, nondestructive µ‐X‐ray fluorescence analysis was carried out on undecalcified histological samples from 13 femoral heads which had undergone surface replacement. These samples were extracted from the patients after gradient time points due to required revision surgery. Samples from nonintervened femoral heads as well as from a MoP resurfaced implant served as controls. Light microscopy and µ‐X‐ray fluorescence analyses revealed that cobalt debris was found not only in the soft tissue around the prosthesis and the bone marrow, but also in the mineralized bone tissue. Mineralized bone exposed to surface replacements showed significant increases in cobalt concentrations in comparison with control specimens without an implant. A maximum cobalt concentration in mineralized hard tissue of up to 380 ppm was detected as early as 2 years after implantation. Values of this magnitude are not found in implants with a MoP surface bearing until a lifetime of more than 20 years. This study demonstrates that hip resurfacing implants with MoM bearings present a potential long‐term health risk due to rapid cobalt ion accumulation in periprosthetic hard tissue. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1855–1862, 2017.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here