z-logo
Premium
Mechanical fatigue performance of PCL‐chondroprogenitor constructs after cell culture under bioreactor mechanical stimulus
Author(s) -
Panadero Juan Alberto,
Sencadas Vitor,
Silva Sonia C. M.,
Ribeiro Clarisse,
Correia Vitor,
Gama Francisco M.,
Gomez Ribelles José Luis,
LancerosMendez Senentxu
Publication year - 2016
Publication title -
journal of biomedical materials research part b: applied biomaterials
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.665
H-Index - 108
eISSN - 1552-4981
pISSN - 1552-4973
DOI - 10.1002/jbm.b.33386
Subject(s) - materials science , tissue engineering , biomedical engineering , scaffold , bioreactor , composite material , extracellular matrix , chemistry , engineering , organic chemistry , biochemistry
Abstract In tissue engineering of cartilage, polymeric scaffolds are implanted in the damaged tissue and subjected to repeated compression loading cycles. The possibility of failure due to mechanical fatigue has not been properly addressed in these scaffolds. Nevertheless, the macroporous scaffold is susceptible to failure after repeated loading–unloading cycles. This is related to inherent discontinuities in the material due to the micropore structure of the macro‐pore walls that act as stress concentration points. In this work, chondrogenic precursor cells have been seeded in poly‐ ε ‐caprolactone (PCL) scaffolds with fibrin and some were submitted to free swelling culture and others to cyclic loading in a bioreactor. After cell culture, all the samples were analyzed for fatigue behavior under repeated loading–unloading cycles. Moreover, some components of the extracellular matrix (ECM) were identified. No differences were observed between samples undergoing free swelling or bioreactor loading conditions, neither respect to matrix components nor to mechanical performance to fatigue. The ECM did not achieve the desired preponderance of collagen type II over collagen type I which is considered the main characteristic of hyaline cartilage ECM. However, prediction in PCL with ECM constructs was possible up to 600 cycles, an enhanced performance when compared to previous works. PCL after cell culture presents an improved fatigue resistance, despite the fact that the measured elastic modulus at the first cycle was similar to PCL with poly(vinyl alcohol) samples. This finding suggests that fatigue analysis in tissue engineering constructs can provide additional information missed with traditional mechanical measurements. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 330–338, 2016.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here