z-logo
Premium
Electronic properties of anodized TiO 2 electrodes and the effect on in vitro response
Author(s) -
Löberg Johanna,
Gretzer Christina,
Mattisson Ingela,
Ahlberg Elisabet
Publication year - 2014
Publication title -
journal of biomedical materials research part b: applied biomaterials
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.665
H-Index - 108
eISSN - 1552-4981
pISSN - 1552-4973
DOI - 10.1002/jbm.b.33065
Subject(s) - anodizing , materials science , oxide , apatite , surface roughness , conductivity , surface finish , osteoblast , simulated body fluid , dielectric spectroscopy , cyclic voltammetry , analytical chemistry (journal) , chemical engineering , scanning electron microscope , electrode , mineralogy , composite material , chemistry , metallurgy , in vitro , electrochemistry , aluminium , chromatography , engineering , biochemistry
For dental implants, improved osseointegration is obtained by modifying the surface roughness as well as oxide morphology and composition. A combination of different effects contributes to enhanced performance, but with surface roughness as the dominant factor. To single out the effect of oxide conductivity on biological response, oxide films with similar thickness and surface roughness but different electronic properties were formed using galvanostatic anodization. Three different current densities were used, 2.4, 4.8, and 11.9 mA cm −2 , which resulted in growth rates ranging from 0.2 to 2.5 V s −1 . The electronic properties were evaluated using cyclic voltammetry and impedance spectroscopy, while the biological response was studied by cell activity and apatite formation. The number of charge carrier in the oxide film close to the oxide/solution interface decreased from 5.8 × 10 −19 to 3.2 × 10 −19 cm −2 with increasing growth rate, that is, the conductivity decreased correspondingly. Cell response of the different surfaces was tested in vitro using human osteoblast‐like cells (MG‐63). The results clearly show decreased osteoblast proliferation and adhesion but higher mineralization activity for the oxide with lower conductivity at the oxide/solution interface. The apatite‐forming ability was examined by immersion in simulated body fluid. At short times the apatite coverage was ∼26% for the anodized surfaces, significantly larger than for the reference with only 3% coverage. After 1 week of immersion the apatite coverage ranged from 73 to 56% and a slight differentiation between the anodized surfaces was obtained with less apatite formation on the surface with lower conductivity, in line with the cell culture results. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 826–839, 2014.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here