Resistance to tearing of calf and ostrich pericardium: Influence of the type of suture material and the direction of the suture line
Author(s) -
Páez José María García,
Carrera Antonio,
Jorge Eduardo,
Millán Isabel,
Cordon Angeles,
Maestro María A.,
Rocha Aurora,
CastilloOlivares José Luis
Publication year - 2004
Publication title -
journal of biomedical materials research part b: applied biomaterials
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.665
H-Index - 108
eISSN - 1552-4981
pISSN - 1552-4973
DOI - 10.1002/jbm.b.20014
Subject(s) - tearing , pericardium , fibrous joint , anatomy , medicine , suture line , surgery , materials science , composite material
The tearing of the valve leaflet of a cardiac bioprosthesis can cause early failure of this device, which is employed to replace a diseased native valve. This report involves the study of the behavior of 312 tissue samples (152 of calf pericardium and 160 of ostrich pericardium) treated with glutaraldehyde and subsequently subjected to tear testing. The samples were cut in the two principal directions: longitudinally, or root to apex, and transversely. They included a series of control samples that were left unsutured, and the remaining samples were repaired with the use of two different suture techniques: a running suture in the direction of the load and a telescoping suture perpendicular to the load. Four commercially available suture materials were employed: Pronova®, nylon, Gore‐Tex®, or silk. The unsutured control samples of both types of pericardium exhibited a similar anisotropic behavior in the tear test. The mean resistance to tearing of the calf pericardium was 24.29 kN m in samples cut longitudinally and 34.78 kN m in those cut transversely ( p = .03); the values were 28.08 kN m and 37.12 kN m ( p = .002), respectively, in ostrich pericardium. The series repaired with the telescoping suture always exhibited greater resistance to tearing, with values that ranged between 44.34 and 64.27 kN for the samples of calf pericardium and from 41.65 to 47.65 kN for those obtained from ostrich. These assays confirm the anisotropic behavior of calf and ostrich pericardium treated with glutaraldehyde when subjected to tear testing, as well as the loss of this behavior in ostrich pericardium after suturing. Suturing techniques, such as the telescoping model, that provide a greater resistance to tearing should be studied for use in the design of the valve leaflets of cardiac bioprostheses made of biological materials. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 69B: 125–134, 2004

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here