z-logo
Premium
Characterization of dermal sensitization potential for industrial or agricultural chemicals with EpiSensA
Author(s) -
Mizumachi Hideyuki,
LeBaron Matthew J.,
Settivari Raja S.,
Miyazawa Masaaki,
Marty Mary Sue,
Sakaguchi Hitoshi
Publication year - 2021
Publication title -
journal of applied toxicology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.784
H-Index - 87
eISSN - 1099-1263
pISSN - 0260-437X
DOI - 10.1002/jat.4076
Subject(s) - local lymph node assay , sensitization , skin sensitization , potency , in vivo , in silico , chemistry , toxicology , chemical compound , pharmacology , in vitro , medicine , microbiology and biotechnology , biochemistry , toxicity , immunology , biology , organic chemistry , gene
The regulatory community is transitioning to the use of nonanimal methods for dermal sensitization assessments; however, some in vitro assays have limitations in their domain of applicability depending on the properties of chemicals being tested. This study explored the utility of epidermal sensitization assay (EpiSensA) to evaluate the sensitization potential of complex and/or “difficult to test” chemicals. Assay performance was evaluated by testing a set of 20 test chemicals including 10 methacrylate esters, 5 silicone‐based compounds, 3 crop protection formulations, and 2 surfactant mixtures; each had prior in vivo data plus some in silico and in vitro data. Using the weight of evidence (WoE) assessments by REACH Lead Registrants, 14 of these chemicals were sensitizers and, six were nonsensitizers based on in vivo studies (local lymph node assay [LLNA] and/or guinea pig studies). The EpiSensA correctly predicted 16/20 materials with three test materials as false positive and one silane as false negative. This silane, classified as weak sensitizer via LLNA, also gave a “false negative” result in the KeratinoSens™ assay. Overall, consistent with prior evaluations, the EpiSensA demonstrated an accuracy level of 80% relative to available in vivo WoE assessments. In addition, potency classification based on the concentration showing positive marker gene expression of EpiSensA was performed. The EpiSensA correctly predicted the potency for all seven sensitizing methacrylates classified as weak potency via LLNA (EC3 ≥ 10%). In summary, EpiSensA could identify dermal sensitization potential of these test substances and mixtures, and continues to show promise as an in vitro alternative method for dermal sensitization.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here