z-logo
Premium
Clogging process by suspended solids during groundwater artificial recharge: Evidence from lab simulations and numerical modelling
Author(s) -
Chu Tong,
Yang Yuesuo,
Lu Ying,
Du Xinqiang,
Ye Xueyan
Publication year - 2019
Publication title -
hydrological processes
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.222
H-Index - 161
eISSN - 1099-1085
pISSN - 0885-6087
DOI - 10.1002/hyp.13553
Subject(s) - clogging , groundwater recharge , hydraulic conductivity , infiltration (hvac) , environmental science , groundwater , permeability (electromagnetism) , hydrology (agriculture) , soil science , aquifer , environmental engineering , geotechnical engineering , geology , materials science , chemistry , soil water , composite material , geography , biochemistry , archaeology , membrane
Permeability reduction of infiltration media due to suspended solid (SS) clogging is the bane of groundwater artificial recharge. To overcome the clogging problem and advance the understanding of the process‐based spatial‐temporal evolution of SS clogging, a 1D laboratory column simulation was carried out, followed by numerical modelling of the experimental data in this study. It was found that clogging caused a reduction in the hydraulic conductivity ( K ) in the upper layer at the beginning and extended deeper to approximately 50 cm, and no reduction in K was detected below 52 cm throughout the experimental period of 129 hr. The most clogged layer spanned from the surface to a depth of 11 cm, and the middle 11–52 cm was characterized by a slight decrease in K. The clogging rates of the different layers decreased with the depth, which was based on data analysis, with the largest value of 0.038 hr −1 in the upper 1 cm. The overall K began to decrease from the surface layer and was increasingly affected by clogging with time. A mathematical model was established to simulate the SS clogging process evolution based on considerations of the attachments and detachments of particles. Then the model was applied to perform several scenario analyses after calibration and validation using the data obtained in the experiment. The simulation results indicated that the SS concentration was much more sensitive than the groundwater depth below the land surface, and 10 days of constant recharge is recommended as the disposal cycle of the clogged layer under the given conditions.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here