z-logo
Premium
A novel integrated hydrogen and natural gas liquefaction process using two multistage mixed refrigerant refrigeration systems
Author(s) -
Mehrpooya Mehdi,
Sadaghiani Mirhadi S.,
Hedayat Nader
Publication year - 2019
Publication title -
international journal of energy research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.808
H-Index - 95
eISSN - 1099-114X
pISSN - 0363-907X
DOI - 10.1002/er.4978
Subject(s) - refrigerant , refrigeration , liquefaction , exergy , heat exchanger , natural gas , liquefied natural gas , heat pump and refrigeration cycle , waste management , liquid hydrogen , coefficient of performance , hydrogen , exergy efficiency , environmental science , transcritical cycle , process engineering , chemistry , engineering , mechanical engineering , organic chemistry
Summary The development and analysis of combined hydrogen and natural gas liquefaction process are reported. Two refrigeration cycles using mixed refrigerants (MRs) are employed. The developed process is capable of generating 290 tons hydrogen and 296 tons liquid natural gas on daily basis. The first refrigeration cycle of the introduced process liquefies 3.5 kg·s −1 normal gaseous hydrogen and 3.5 kg·s −1 normal natural gas at room temperature and 21 bar to −195°C with the consumed power of 0.643 kWh/kg LH2 ,kg LNG . The second refrigeration cycle cools down the hydrogen and natural gas to −253°C with the consumed power of 1.662 kWh/kg LH2 ,kg LNG , leading to a lower total consumed power than that of the identical liquefaction processes. The use of novel and appropriately mixed refrigerants based on the configuration, and the thermal design of expanders and heat exchangers fora wide range of temperatures are the innovations of the process. Additionally, the refrigerant compositions of refrigeration cycles are novel. The energy analysis indicated that the coefficient of performance (COP) for the developed process is 0.2442, which is notably high compared with the COP of other identical processes (typically less than 0.1797). The exergy analysis revealed that the overall exergy efficiency of the liquefaction process is 62.54%. Highlight edited A novel integrated hydrogen and natural gas liquefaction process is introduced. The process can generate 290 tons hydrogen and 296 tons liquid natural gas per day. Total power consumptions of the process are 4.165 kWh/kg LH2 ,kg LNG . Coefficient of performance (COP) for the developed process is 0.2442, which is notably high compared with the COP of other identical processes. Overall exergy efficiency of the liquefaction process is 62.54%.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here