Premium
Synthesis and Application of PHT‐TiO 2 Nanohybrid for Amperometric Glucose Detection in Human Saliva Sample
Author(s) -
Kadian Sachin,
Arya Brahm Dutt,
Kumar Sumit,
Sharma Shailesh N.,
Chauhan Rishi Pal,
Srivastava Ananya,
Chandra Pranjal,
Singh Surinder P.
Publication year - 2018
Publication title -
electroanalysis
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.574
H-Index - 128
eISSN - 1521-4109
pISSN - 1040-0397
DOI - 10.1002/elan.201800207
Subject(s) - biosensor , cyclic voltammetry , glucose oxidase , materials science , dielectric spectroscopy , chronoamperometry , detection limit , fourier transform infrared spectroscopy , amperometry , nanocomposite , nanoparticle , indium tin oxide , scanning electron microscope , analytical chemistry (journal) , electrode , nuclear chemistry , chemical engineering , nanotechnology , electrochemistry , chemistry , chromatography , thin film , composite material , engineering
Nanoparticles and their composites are considered to play a significant role in the development of electrochemical biosensors. In the present work, we have synthesized titanium dioxide (TiO 2 ) nanoparticles comprising poly (3‐hexylthiophene) (PHT) nanohybrid for the fabrication of glucose biosensor. The thin film of hybrid PHT/TiO 2 nano‐composite was deposited onto indium‐tin‐oxide (ITO) glass substrate followed by immobilization of glucose oxidase (GOx). The developed sensor was characterized using X‐Ray Diffraction, Fourier Transform Infrared Spectroscopy, UV‐visible spectroscopy, cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. The electrochemical response of the nanocomposite coated electrode was studied which shows a quasi‐reversible electrochemical behavior. The experimental conditions for glucose detection were optimized in terms of GOx immobilization time, GOx concentrations, temperature, and pH, in order to obtain maximum sensitivity. Under the optimized experimental conditions, the ITO/TiO 2 /PHT/GOx sensor probe displays excellent catalytic activity towards glucose with the response time of <10.0 sec, showing its robustness for direct clinical analysis. Chronoamperometry was performed for the quantitative detection of glucose which displays the linear dynamic range between 1–310 mg/dL with the detection limit of 0.62±0.02 mg/dL. The developed biosensor was successfully applied to detect glucose in human saliva samples without any pre‐treatment step. Importantly, the detection range of the designed biosensor was in range of normal and clinical salivary glucose levels. Interferences due to nontarget biochemicals was investigated and long term stability of the sensor probe was evaluated.