Investigations in bioanalytical chemistry part VIII: Derivative adsorption chronopotentiometry of the Cu II complex with adenine, adenosine and adenosine monophosphate
Author(s) -
Zhao Xin,
Jin Wenrui,
Tang Jian
Publication year - 1996
Publication title -
electroanalysis
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.574
H-Index - 128
eISSN - 1521-4109
pISSN - 1040-0397
DOI - 10.1002/elan.1140080413
Subject(s) - adenosine , bioanalysis , chemistry , adsorption , adenosine monophosphate , derivative (finance) , inorganic chemistry , nuclear chemistry , chromatography , biochemistry , economics , financial economics
The derivative adsorption chronopotentiometric characteristic of the Cu II complex with adenine, adenosine and adenosine monophosphate (AMP) is discussed. The optimum experimental conditions and the linear ranges were studied. The detection limits of adenine, adenosine and AMP were 2.2 × 10 −9 , 4.5 × 10 −8 and 4.6 × 10 −8 mol/L, respectively.