Multi‐objective optimization strategy based on desirability functions used for electrophoratic separation and quantification of rosiglitazone and glimepiride in plasma and formulations
Author(s) -
Hefnawy Mohamed M.,
Sultan Maha A.,
AlJohar Haya I.,
Kassem Mohamed G.,
AboulEnein Hassan Y.
Publication year - 2012
Publication title -
drug testing and analysis
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.065
H-Index - 54
eISSN - 1942-7611
pISSN - 1942-7603
DOI - 10.1002/dta.260
Subject(s) - glimepiride , chromatography , capillary electrophoresis , chemistry , detection limit , capillary action , rosiglitazone , analytical chemistry (journal) , materials science , medicine , type 2 diabetes , composite material , diabetes mellitus , endocrinology , biochemistry , receptor
Multiple response simultaneous optimization employing Derringer's desirability function was used for the development of a capillary electrophoresis method for the simultaneous determination of rosiglitazone (RSG) and glimepiride (GLM) in plasma and formulations. Twenty experiments, taking the two resolutions, the analysis time, and the capillary current as the responses with three important factors—buffer morality, volte and column temperature—were used to design mathematical models. The experimental responses were fitted into a second order polynomial and the six responses were simultaneously optimized to predict the optimum conditions for the effective separation of the studied compounds. The separation was carried out by using capillary zone electrophoresis (CZE) with a silica capillary column and diode array detector at 210 nm. The optimum assay conditions were 52 mmol l −1 phosphate buffer, pH 7, and voltage of 22 kV at 29 °C. The method showed good agreement between the experimental data and predictive value throughout the studied parameter space. The assay limit of detection was 0.02 µgml −1 and the effective working range at relative standard deviation (RSD) of ≤ 5% was 0.05–16 µgml −1 (r = 0.999) for both drugs. Analytical recoveries of the studied drugs from spiked plasma were 97.2–101.9 ± 0.31–3.0%. The precision of the assay was satisfactory; RSD was 1.07 and 1.14 for intra‐ and inter‐assay precision, respectively. The proposed method has a great value in routine analysis of RSG and GLM for its therapeutic monitoring and pharmacokinetic studies. Copyright © 2011 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here